VCC-FC20V49PCL
Rev.900-734-33
©2014 CIS Corporation. All rights reserved.
12
Function
Address Data
Manual Shutter Control
009&010
0
~
480:
1/50000s
~
1/500s
481
~
2047: 480
※
The setting will be 1 line when 0 is set.
Exposure Time
=
The set value
×
1line Time [s]
1line Time [s]
= ((output pixels/2tap)+5)
×
1/79.99MHz
At full frame scan,
output pixels = 480
1line Time
≒
4.06
μ
s
※
Address 002 data shall be 016.
Address 009 MSB and Address 010 LSB make 11bit in total.
Trigger Polarity
011
0:
Positive Input
1:
Negative Input
2
~
255:
Positive Input
No Function
012
0: Fixed. Do not change.
Output Data Selection
013
0: 8bit output data (RAW)
1: 10bit output data (RAW)
2
~
255: 8bit output data
Trigger Input Signals
Camera Internal H Sync ON/OFF
014
2: OFF
3: ON
Vertical Partial Scan
Start Position
016&017
0
~
Max. Value
※
1line/step
※
Max. value shall be limited according to the formula below.
480 (Vertical Partial Scan output max. lines – Vertical Partial Scan output lines)
※
Address 005 data shalla be 002.
Address 016 MSB and Address 017 LSB make 11bit in total.
Vertical Partial Scan
Output Lines
019&020
0
~
480:
1line/step
Min.:1line/Max :480 lines
481
~
2047: 480
※
1 line shall be set when 0 is set.
Address 019 MSB and Address 020 LSB make 11bit in total.
※
Address 005 data shalla be 002.
Remote Communication
Baud Rate Setting
030
0: 9600bps
1: 19200bps
2: 38400bps
3: 57600bps
4: 115200bps
5
~
255: 9600bps
Data Save
032
Input 083 to save address 000
~
031 to EEP-ROM.