background image

VCC-FC20V49PCL                                                                                                                                             

         

  Rev.900-734-33 

 

©2014 CIS Corporation. All rights reserved.

                                                                                                                                                                 

 

17 

LVAL Output

10 H

FVAL Output

DVAL Output

n H

·   ·   ·

Video Output

·   ·   ·   ·   ·   ·   ·

Exposure Time

2 H

·   ·   ·   ·   ·   ·   ·

·   ·   ·   ·   ·   ·   ·

2 H

n H (Max.)

Video Output

s s+1

s+n

-1

s+n

s+n

-2

s+n

-3

s+n

-1

s+n

s+n

-2

480

·   ·   ·

FVAL Output

Partial scan (vertical 1/2)  n: 240H
Manual partial scan      n: any

· At full frame scan 

· At vertical partial scan

·   ·   ·

·   ·   ·

0

1

2

119 120

359 360

479

478

2 H

Partial scan (vertical 1/2) s: 120H
Manual partial scan         s: any

480
(The max vertical partial 
scan output lines)

n = 400
 The set vertical partial scan   
 output lines

0 ~  80 
Vertical partial scan
Starting position
Setting range

s = 90 (invalid)
 vertical partial scan
 starting position
 Set value

s = 80 (with limitation)
 vertical partial scan
 starting position

0

80

90

479

 

9.

 

Partial Scan Mode 

 

 

Vertical Partial Scan 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

s:

 

  Vertical partial scan starting position (address 016

017) 

 

 

 

n:

 

  Vertical partial scan output lines (address 019

020) 

Scan Mode (address:005) 

Vertical Sync. Frequency (Hz) 

0:Full frame scan mode 

480 

  502.29 

1:Partial scan mode (Vertical 1/2) 

120 

240 

  984.49 

2:Manual partial scan mode   

Any 

any 

79.99MHz /((Vertical partial scan output lines +10)×(325)) 

 

The max value of vertical partial scan starting position is limited with the formula below since vertical partial scan output   

line has priority.     

   

The max value of vertical partial scan starting position 

      =480(The max value of vertical partial scan output line) –

 

Vertical partial scan output lines 

 
(Ex.) When 400 is set as vertical partial scan output lines, the max value of vertical partial scan starting position will be 

480-400 = 80. 
If vertical partial scan starting position is set to 90 with this time, vertical partial scan output line has priority so that vertical 
partial scan starting position shall be limited to 80. 

 
 
 
 
 
 
 
 
 
 
 

  At manual partial scan mode, manual shutter value to be set shall meet the following conditions. 

 

The set manual shutter lines

  ≦ 

Vertical partial scan output lines 

 

If the condition above is not met, shutter lines to be set will be the same number as vertical partial scan output lines. 

Содержание VCC-FC20V49PCL

Страница 1: ...V49PCL Rev 900 734 33 2014 CIS Corporation All rights reserved Camera link I F 29mm cubic VGA High Speed Color CMOS PoCL Camera VCC FC20V49PCL Product Specification Operational Manual CIS Corporation...

Страница 2: ...t Assignment Base Configuration 10 6 Function Settings 11 7 External Connector Pin Assignment 13 7 1 26pins Mini Camera Link Connector 12226 1100 00 PL SUMITOMO 3M 13 8 Timing Chart 14 8 1 Horizontal...

Страница 3: ...old places operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to un...

Страница 4: ...supply voltage may cause noises on the video signals The rising time of camera power supply voltage shall be less than 10V Max 60ms Please avoid noises like chattering when rising In case of abnormal...

Страница 5: ...amera to a metalic part would be effective 4 Product Outline VCC FC20V49PCL is an industrial Color high speed digital video camera module utilizing a global shutter type CMOS sensor Interface of VCC F...

Страница 6: ...ains in optical system No dust or stain shall be detected on the testing screen with setting the camera aperture at F16 10 Power requirements DC 12V 10 Max voltage shall not be exceeded 15V 11 Power c...

Страница 7: ...wo conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 22 Durability Vibration...

Страница 8: ...Trigger input Polarity POSI NEGA Selectable Min width of trigger pulse 10 s Camera Link input LVDS CC1 input Camera Link connector 4 Serial Communication SerTC Serial to Camera Camera Link input LVDS...

Страница 9: ...considered 5 4 Video Output Format VGA 500fps Mode 2Tap Interleaved Bayer Pattern GBRG At full frame scan At manual partial scan mode Bayer Pattern changes per 1 line according to the set vertical sta...

Страница 10: ...Port A5 DA bit5 DA bit5 Port A6 DA bit6 DA bit6 Port A7 DA bit7 MSB DA bit7 Port B0 DB bit0 LSB DA bit8 Port B1 DB bit1 DA bit9 MSB Port B2 DB bit2 Not in use Port B3 DB bit3 Not in use Port B4 DB bi...

Страница 11: ...nual White Balance Refer to the Address 006 007 5 255 Through Trigger Shutter Mode 004 0 Normal Shutter Mode Trigger Shutter Mode OFF 1 Fixed Trigger Shutter Mode Shutter speed can be set with address...

Страница 12: ...1 10bit output data RAW 2 255 8bit output data Trigger Input Signals Camera Internal H Sync ON OFF 014 2 OFF 3 ON Vertical Partial Scan Start Position 016 017 0 Max Value 1line step Max value shall be...

Страница 13: ...or Pin Assignment 7 1 26pins Mini Camera Link Connector 12226 1100 00 PL SUMITOMO 3M Pin No Pin No 1 DC 12V 14 GND 2 X0 15 X0 3 X1 16 X1 4 X2 17 X2 5 Xclk 18 Xclk 6 X3 19 X3 7 SerTC 20 SerTC 8 SerTFG...

Страница 14: ...8 477 1 2 489 490 488 487 2 H 2 H Min 1H Max 480 H 489 490 488 487 490 H LVAL Output 5CLK Video Output DVAL Output 1H 325 CLK 320 CLK CLK 79 99MHz 1 2 3 4 5 6 8 7 633 634 635 636 637 638 640 639 5CLK...

Страница 15: ...g video signals However trigger signals for exposure to start the next video output prior to the completion of video transmission for the prior video output signals cannot be accepted If the edge part...

Страница 16: ...er limitation but noises such as dark noises and shadings may be noticeable at long time exposure Triggers can be accepted even when outputting video signals However trigger signals for exposure to st...

Страница 17: ...5 s n Vertical Sync Frequency Hz 0 Full frame scan mode 0 480 502 29 1 Partial scan mode Vertical 1 2 120 240 984 49 2 Manual partial scan mode Any any 79 99MHz Vertical partial scan output lines 10 3...

Страница 18: ...to the address table of 6 Function setting 000 255 0Dh W Write mode C Camera mode Camera No Please send the common code 000000 consist of 6 bytes of characters numeric strings The returned data from...

Страница 19: ...CR to confirm the end of the command 11 Initial Settings Function Address Data Gain 001 0 0dB Shutter 002 0 1 500s White Balance 003 0 Through Trigger Mode 004 0 Normal Shutter Mode Trigger Shutter Mo...

Страница 20: ...The center of effective pixels shall be within f 0 6 to the center of C lens mount Inclination of effective pixels Theta to datum plane shall be 0 5 Dimensions from datum plane to the center of the le...

Страница 21: ...VCC FC20V49PCL Rev 900 734 33 2014 CIS Corporation All rights reserved 21 13 Dimensions...

Страница 22: ...er problems resulting from use of equipment or software that is not specified In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party su...

Отзывы: