VCC-5CL5M/R
Rev.905-0073-01
©2017 CIS Corporation. All rights reserved.
16
Preset Trigger Shutter Time ((Preset Trigger Shutter Mode)
Manual Shutter Time Setting Values
Address
Data
Description
23
0
1
2
3
4
5
6
7
8
9
10
11
Shutter 1tap/2tap/3tap
1/30s
1/60s
1/100s
1/150s
1/300s
1/600s
1/1250s
1/2500s
1/5000s
1/10000s
1/20000s
1/50000s
Time
33330μs
16670μs
10000μs
6670μs
3330μs
1670μs
800μs
400μs
200μs
100μs
50μs
20μs
15
Manual Shutter as Preset Trigger mode Setting value with the Address 24.
Address
Data
Description
24
12bit
24bit
Continuous shutter mode
Setting range = (Total line) – 2 line step
Shutter_time_3tap (μs) = (Setting value) x 1line: 13.4μs + 13.7μs
Shutter_time_2tap (μs) = (Setting value) x 1line: 16.5μs + 13.7μs
Shutter_time_1tap (μs) = (Setting value) x 1line: 33.0μs + 13.7μs
Trigger shutter mode 1/50000s
~
1/5s
Setting range = 6μs
~
200ms 1μs step
Preset Shutter time (μs) = (Setting value) + 14μs
Width Shutter time (μs) = (Trigger Pulse Width) + 14μs