VCC-120CXP1M/VCC-120CXP1R Preliminary Rev.905-0120-Z1
©2017 CIS Corporation. All rights reserved.
14
4.9.
Strobe Pulse Control
□
This is to output the timing for exposure or reading out.
Wide Strobe
This is to output from the start of exposure to the completion of reading out.
Valid only when external trigger is used. (Always assert at free run).
Narrow Strobe This is to output from the completion of exposure to the start of reading out.
Valid only when long time exposure. (Always assert at standard exposure).
Manual Strobe This is to set rising edge and falling edge of signals with any preferred timing.
No Strobe
This is to stop outputting.
Acquisition Control
StrobeSelector
Wide Strobe
Narrow Strobe
Manual Strobe
No Strobe
StrobeActivation
Positive
Negative
StrobeDelay
Specify the delay from the trigger to the strobe pulse
with uS.
Note) If a line number, more than trigger cycle was set,
abnormal operation may occur.
StrobeWidth
Specify the strobe pulse width with uS.
Note) If a line number, more than trigger cycle was set,
abnormal operation may occur.
VD
Accumlation Period
previous
frame
Read out
Vscan
vdi
hdi
…
Reset
Vscan
trig
Wide strobe
Narrow strobe
Manual strobe
strobe_width
strobe_dly