VCC-120CXP1M/VCC-120CXP1R Preliminary Rev.905-0120-Z1
©2017 CIS Corporation. All rights reserved.
10
4.8.
Trigger Mode
TriggerSelector
:
Trigger selector
This is to select how to start capturing video out of the followings.
AcquisitionStart
:
Free run mode [Internal sync. mode]
FrameStart
:
Trigger mode
[External sync. mode]
Off
:
Stop operation
TriggerActivation
:
Trigger activation
This is to select the trigger polarity out of the followings.
TriggerSelector
が
FrameStart
の時、操作可能になります。
RisingEdge
:
Rising edge
[External sync. mode]
FallingEdge
:
Falling edge
[External sync. mode]
TriggerSource
:
Trigger source
This is to select where to input the external trigger.
LinkTrigger0
:
External trigger input from the CoaXPress Host Device.
Please refer to the specification manuals of the Host Device such as
frame grabber board to know how to generate triggers.
※
Set TriggerActivation to RisingEdge.
Line0
:
External trigger input from the 12pins circular connector.
TriggerSoftware
:
Software trigger
A trigger is generated in the camera and capture images for one frame when this command is executed.
This command is valid when TriggerSelector is at FrameStart.
Acquisition Control
TriggerSelector
AcquisitionStart
FrameStart
Off
TriggerActivation
RisingEdge
FallingEdge
TriggerSource
LinkTrigger0
Line0
TriggerSoftware Execute