Cirs Dynamic Phantoms 008A Скачать руководство пользователя страница 13

13

OVERALL DIMENSIONS

:

67 cm x 32 cm x 28 cm  (26’ x 13’ 11’)

OVERALL WEIGHT:

17.2 kg  (37.9 lb)

POWER:

110-250 VAC, 50/60 Hz

AMPLITUDE, IS:

± 25 mm

AMPLITUDE, AP/LR:

± 5 mm

AMPLITUDE, SURROGATE: 

± 25 mm

MAX. SURROGATE PLATFORM LOAD

5.4 kg  (12 lb)

MOTION ACCURACY:

± 0.1 mm

CYCLE TIME:

 

1 - 

 (adjusted based on amplitude)

Model 008A Specifications

Part No. Qty Component Description

008A

1

Dynamic Thorax Phantom Body with 3D spine 

(Dosimeter & QA rods not included )

1

Dynamic Motion Controller with firmware installed

(110 - 220V, 50 - 60Hz)

1

Actuator base plate assembly

1

3rd axis gating device (mounted to actuator base 

plate assembly)

CIRS Motion Control Software USB

1

Cable kit: USB 3.0 Gigabit Ethernet Adapter, Net-

work cable CAT5e, 75’, DB 25 male to male cable, 

DB 9 male to male cable, Power cord

Accessories Kit: 4 in 1 screwdriver, push rod, 

fasteners pack, 2 spare fuses

1

Adjustable legs kit: level, 4 adjustable legs with feet, 

post with screw 

User’s guide (PDF user guide and catalog included 

on provided USB) 

1

Carry Case

OPTIONAL ACCESSORIES

INCLUDED WITH MODEL 008A

Note: Customers must complete their order with the purchase of at least one 

(1) interchangeable insert option. *Refer to separate CIRS cavity and plug 

code list for available chamber cavities.

Part No.

Description

008A-05

MOSFET configured lung equivalent rod with set of 3 target 

inserts 

008A-

06-CV*

MICRO CHAMBER configured lung equivalent rod with set of 

3 target inserts 

008A-08

Radiochromic film configured lung equivalent rod

008A-11

GEL DOSIMETRY configured lung equivalent rod with CIRS 

Model B-9, Dose Gel Container

008A-12

4D CT QA Device

008A-14

Lung equivalent Imaging Rod with set of 3 target inserts

008A-15

PET/CT configured lung equivalent rod with set of 3 target 

inserts

008A-17

Adjustable legs kit

008A-19

Ball Cube configured lung equivalent rod for film dosimetry

008A-22

SBRT Rod with set of 3 target inserts

008A-24

OSL Dosimetry Rod with 3 cm Target insert

008A-153

Replacement Push Rod

008A-125

Chest plate with reflective 11.5 mm tracker balls

008-18

Model 008 upgrade to 008A

008A-253

Cable CAT5E 150 Feet for Dynamic Phantom (008A, 008M,)

Содержание Dynamic Phantoms 008A

Страница 1: ...IMAGE ACQUISITION TREATMENT PLANNING DOSE DELIVERY USER GUIDE Dynamic Phantoms Model 008A 008A 20 18023 A 18043 A 900 Asbury Ave Norfolk Virginia 23513 USA Tel 757 855 2765 WWW CIRSINC COM...

Страница 2: ...oval of Ball Cube 7 Model 008A 18023 A 18043 A Cables and Connections 8 4D CT QA Insert Set Up 9 Setup notes for Dynamic Phantoms with controller connecting to a PC using an Ethernet connection 10 CIR...

Страница 3: ...rd axis actuator Model 18023 A shares some components with the CIRS Model 008A Dynamic Thorax Phantom As with the Model 008A target and surrogate motion are inde pendently controlled with CIRS Motion...

Страница 4: ...en connecting this product to a power source If you do not know whether the outlet is grounded check with a qualified electrician Do not remove ground prong Do not install or use this product near wat...

Страница 5: ...he case and set aside Drop N Tell shipping damage indicator shows when a case has been dropped in transit and contains potential dam aged goods The sensor displays a red arrow when applied before ship...

Страница 6: ...d is aligned with screw hole on actuator rod 5 Use thumb screw to secure lung rod to actuator rod 6 Push lung rod towards the motor box Visually check gap around the rod It should appear consistent If...

Страница 7: ...ll Cube is removed Do not use other tools for this purpose as they may damage the surface of the Ball Cube which is fragile 5 Use a screw driver to tighten the 4 nylon screws on the cup 4 The Model 18...

Страница 8: ...ting device to back of actuator Model 008A 18023 A 18043 A Cables and Connections A Adjustable legs kit See B and C for mounting B Prior to attaching phantom body care fully lay base plate with actuat...

Страница 9: ...tart angle 0 degree For AP IS 0 LR 0 AP per your choice start angle 90 degree 5 Run phantom and perform 4D CT imag ing Obtain test results from the 4D CT sorted images Report results as the difference...

Страница 10: ...d above 1 To install the necessary driver unzip the USB to Network Adapter folder found on the provided USB drive or download the zipped folder from the CIRS website Archive to a known location and se...

Страница 11: ...0 249 8 Once the IP address is entered click OK Connect the PC to the Controller using the provided Ethernet cable by inserting one end of the cable in the controller s Ethernet port and the other on...

Страница 12: ...optional The software automatically creates a log file where data about wave form parameters are saved The log file is usually located under the current user in the Application Data folder A Windows O...

Страница 13: ...g included on provided USB 1 Carry Case OPTIONAL ACCESSORIES INCLUDED WITH MODEL 008A Note Customers must complete their order with the purchase of at least one 1 interchangeable insert option Refer t...

Страница 14: ...isfied with your purchase for any reason please contact your local distributor prior to returning the product Visit https www cirsinc com distributors to find your local distributor If you purchased y...

Страница 15: ...15 NOTES...

Страница 16: ...tice Publication DYNAMIC UG 110320 Computerized Imaging Reference Systems Inc has been certified by UL DQS Inc to ISO 13485 2016 Certificate Registration No 10000905 MP2016 COMPUTERIZED IMAGING REFERE...

Отзывы: