Cirs Dynamic Phantoms 008A Скачать руководство пользователя страница 12

12

CIRS MOTION CONTROL SOFTWARE SYSTEM 

REQUIREMENTS

Windows XP

® 

/ Vista / Windows 7/ Windows 8/ Windows 10 

(32 and 64 Bit)
Pentium 3

®

 or equivalent 

512 MB RAM,  2 MB of available disk space

INTRODUCTION

CIRS Motion Control is an application which allows you to control 
the movement of the CIRS Model 008A Dynamic Thorax Phantom 
and model 008PL Dynamic Platform. With CIRS Motion Control, you 
can quickly set up a movement based on a library of pre-defined 
motions, including Sin, Cos4, Cos6, Sawtooth, Sharkfin, Hyster-
esis ( Model 008A only) and Continuous Drift, Transient Excursion, 
Persistent Excursion, High-Frequency Excursion, or you can import 
custom motion data from any tab-delimited or comma- separated 
text file. CIRS Motion Control also allows you to save any motion 
to easily access the same parameters for repeated calibration and 
testing.

INSTALLATION

The CIRS Motion Control application requires the Trio PC Motion 
library, which allows the computer to recognize the Trio controller 
board in the Dynamic Phantom or Platform.  To install the Trio PC 
Motion library, double-click Trio_PC_Motion_ActiveX_2_6_15_Setup 
and follow the steps in the InstallShield Wizard.

To install CIRS Motion Control, double-click MotionControl- 

Setup or Setup and follow the steps in the Setup Wizard.  The 

Microsoft.NET Framework Version 3.5 is required for the ap-

plication to run .

GENERAL USE

The CIRS Motion Control Software is preinstalled on the optional 
computer.  Help can be launched from 

Help Menu

.  A copy of the

software is included on a USB drive.

CIRS does not support 3rd party equipment.  Please refer to the 
included documents for warranty and service information for the 
ACER brand computer (computer optional). 

The software automatically creates a log file where data about wave- 
form parameters are saved. The log file is usually located under the 
current user in the Application Data folder.  A Windows OS search 
function can be used to find the log file.  Searching hidden files and 
folders should be enabled.

The log file provides a record of the motion history of the device and 
can be used as objective evidence that proper QA was performed.

CIRS Motion Control Software

SOFTWARE USER MANUAL & SOFTWARE UPGRADES

CIRS Motion Control software has an online user manual. After 
software installation, a copy may be viewed and downloaded using 
either the “Check for Updates” button from Help Menu and selecting 
“Motion Control User Manual.pdf” or by pointing a web browser to 
the CIRS Software Updates webpage: http://www.cirsinc.com/Mo-
tionControlUpdates/Motion_Control_User_Manual.pdf 

If the end-user is offline during use of the phantom, it is recom-
mended that a copy of the CIRS Motion Control User Manual is 
downloaded and saved. Once a copy of the manual is saved in a 
known location, the PDF document can be opened and viewed in a 
window separate from the CIRS Motion Control software window to 
aid in phantom set up and use. 

The user manual is regularly updated to incorporate new information 
based on the addition and/or modification of features as well as end-
user feedback. 

CIRS recommends that the end-user routinely check the CIRS Soft-
ware Update webpage using the “Check for Updates” button from 
Help Menu. This page indicates the current software version. The 
latest free software upgrade is posted as soon as it becomes avail-
able. Instructions for updating the software are also posted. Please 
note, when updating WIndows operating system, the controller may 
need to be updated as well, requiring return to CIRS. See https://
www.cirsinc.com/software/motion-control/ for more information. 

Содержание Dynamic Phantoms 008A

Страница 1: ...IMAGE ACQUISITION TREATMENT PLANNING DOSE DELIVERY USER GUIDE Dynamic Phantoms Model 008A 008A 20 18023 A 18043 A 900 Asbury Ave Norfolk Virginia 23513 USA Tel 757 855 2765 WWW CIRSINC COM...

Страница 2: ...oval of Ball Cube 7 Model 008A 18023 A 18043 A Cables and Connections 8 4D CT QA Insert Set Up 9 Setup notes for Dynamic Phantoms with controller connecting to a PC using an Ethernet connection 10 CIR...

Страница 3: ...rd axis actuator Model 18023 A shares some components with the CIRS Model 008A Dynamic Thorax Phantom As with the Model 008A target and surrogate motion are inde pendently controlled with CIRS Motion...

Страница 4: ...en connecting this product to a power source If you do not know whether the outlet is grounded check with a qualified electrician Do not remove ground prong Do not install or use this product near wat...

Страница 5: ...he case and set aside Drop N Tell shipping damage indicator shows when a case has been dropped in transit and contains potential dam aged goods The sensor displays a red arrow when applied before ship...

Страница 6: ...d is aligned with screw hole on actuator rod 5 Use thumb screw to secure lung rod to actuator rod 6 Push lung rod towards the motor box Visually check gap around the rod It should appear consistent If...

Страница 7: ...ll Cube is removed Do not use other tools for this purpose as they may damage the surface of the Ball Cube which is fragile 5 Use a screw driver to tighten the 4 nylon screws on the cup 4 The Model 18...

Страница 8: ...ting device to back of actuator Model 008A 18023 A 18043 A Cables and Connections A Adjustable legs kit See B and C for mounting B Prior to attaching phantom body care fully lay base plate with actuat...

Страница 9: ...tart angle 0 degree For AP IS 0 LR 0 AP per your choice start angle 90 degree 5 Run phantom and perform 4D CT imag ing Obtain test results from the 4D CT sorted images Report results as the difference...

Страница 10: ...d above 1 To install the necessary driver unzip the USB to Network Adapter folder found on the provided USB drive or download the zipped folder from the CIRS website Archive to a known location and se...

Страница 11: ...0 249 8 Once the IP address is entered click OK Connect the PC to the Controller using the provided Ethernet cable by inserting one end of the cable in the controller s Ethernet port and the other on...

Страница 12: ...optional The software automatically creates a log file where data about wave form parameters are saved The log file is usually located under the current user in the Application Data folder A Windows O...

Страница 13: ...g included on provided USB 1 Carry Case OPTIONAL ACCESSORIES INCLUDED WITH MODEL 008A Note Customers must complete their order with the purchase of at least one 1 interchangeable insert option Refer t...

Страница 14: ...isfied with your purchase for any reason please contact your local distributor prior to returning the product Visit https www cirsinc com distributors to find your local distributor If you purchased y...

Страница 15: ...15 NOTES...

Страница 16: ...tice Publication DYNAMIC UG 110320 Computerized Imaging Reference Systems Inc has been certified by UL DQS Inc to ISO 13485 2016 Certificate Registration No 10000905 MP2016 COMPUTERIZED IMAGING REFERE...

Отзывы: