Setting Up the CH+ Tester  

 

Computer Requirements for a Station or Network Server

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

If you plan on using a Networked Server: 

Accessing test data from a network is a nice way to make sure that all the stations on the 
production floor use the same test information.  The requirements for a network server are the 
same as a workstation with the exception that  the server must use either 2000 or 2003 
Windows Server software.  The computer that runs the network database should be dedicated 
to running the database software.  The network database server should not be used as a 
workstation.   

 

You may want to add optional accessories

 

These accessories can be purchased through computer and office supply stores.   Each 
accessory is easy to integrate with your computer and  CH+ test system. 

 

 

‰

 

Sheet Printer 

Used to print test 
reports and fixturing 
information. 

 

‰

 

Label Printer 

Allows printed labels 
to be applied to the 
tested product. 

‰

 

PC Network Card 

Allows the test 
stations to share 
test information 
with each other. 

‰

 

Barcode Scanner 

Used on the 
production floor 
instead of the mouse.

 

‰

 

Computer CPU 

1.6 GHz or better. 

‰

 

Mouse 

Required for installation and 
test setup.  Can be replaced 
with a barcode scanner on the 
production floor.

 

‰

 

Free Disk Space 

Minimum: 5 GB 
Recommended:  10 GB  

‰

 

Windows Environment

Windows XP Professional,  
Windows 2003 Server, or 
Windows 2000 Server 

 

‰

 

Monitor 
Recommended:

 1024X 768

‰

 

Speaker & Sound Card

 

Required

 

‰

 

Serial Port or USB*

 

1 Required  

*

If no serial port, must use  

Keyspan USB-to-Serial Adapter USA-
19HS  

 

‰

 

CD ROM Drive 

Required 

‰

 

Video Card 

64 Meg On Board Memory

‰

 

Internet Connection 

Not required, but can facilitate 
support issues.  

‰

 

RAM 

Minimum: 1 GB  

Содержание CH+

Страница 1: ...started guide and an on line help system manual included on the easy wire software CD There is no printed user s manual for the easy wire software You should have received For using the Signature CH...

Страница 2: ...easy to integrate with your computer and CH test system Sheet Printer Used to print test reports and fixturing information Label Printer Allows printed labels to be applied to the tested product PC Ne...

Страница 3: ...ls however occasional mild electric shock may be experienced Small shocks only occur during a hipot test when the operator touches an energized connection point Any shock from the tester may result in...

Страница 4: ...k cover plates 3 Stack the scanner box es on top of the base unit Important The base unit is not designed to support the weight of more than 4 scanner boxes For more than 4 scanner boxes we suggest yo...

Страница 5: ...in the cover plate screws 8 Set up the computer that will operate the CH CRT video monitors florescent lights and equipment motors are electrically noisy devices and should be kept at least 2 feet fr...

Страница 6: ...another make or model we have discovered that many other USB converters do not work with our equipment This adapter out of many that we have tried has consistently performed without any difficulties...

Страница 7: ...strip into a grounded wall outlet You shouldn t have to worry about overloading a single outlet Even a 5000 point CH system uses less than 500 watts of power If you are rack mounting the CH System pr...

Страница 8: ...ch box separately from the rack 1 Pry up the plastic plunger in the center of each foot then you can remove the foot 2 Install the rack mounting brackets on the front of each box 3 Mount the boxes on...

Страница 9: ...asy wire software and the database from the network This method greatly simplifies installing and updating the easy wire software For this install do the section entitled Installing the Software only...

Страница 10: ...art and then Run Type d install exe where d is the CD ROM drive Then click OK 3 If this window appears click on Terminate Interbase Server If this window appears the following window should say that t...

Страница 11: ...his station or server Note If this is a station or network database installation the station name entered here will be used on reports generated by this station If needed you can change the station na...

Страница 12: ...folder 3 Drag Shortcut to easywire to the desktop 4 Using Windows File Explorer browse to the Help folder under the Cirris folder 5 Right click on CirrisHelp htm From the pop up menu select Create Sh...

Страница 13: ...2 Place the CD into the CD ROM drive and wait After a moment the CD should auto load If the software does not auto load from the Windows taskbar click on Start then on Run Type d install exe where d i...

Страница 14: ...n be used to identify this server Then click Next 9 After the installation is complete click Finish Before proceeding to the next section check that the folder c Cirris Server Database on the network...

Страница 15: ...ver Database directory 5 If you previously created tests on stand alone stations you can copy the test programs from one stand alone station to the network database Check this box only if this situati...

Страница 16: ...appears Unless this is a network station where password security has previously been setup the default is no password 2 Click on OK Passwords can be set up to identify users and prevent unauthorized...

Страница 17: ...st computer The easy wire software relies heavily on sound prompts to provide feedback to the operator Troubleshooting a Red Status Indicator If you have a red status indicator in the easy wire main m...

Страница 18: ...3 The Windows sound mute box is not checked and the volume is adjusted Note To access the Windows sound control click on the speaker symbol in the bottom right corner of the Windows screen If none of...

Страница 19: ...asy servicing Should your Cirris tester require service as directed by Cirris support personnel you may need to send the affected module or the entire tester back to Cirris for repair If needed during...

Страница 20: ...dded level of operator safety Conditions for Operation Your CH Tester is intended to be used indoors at a temperature of 10 to 40 degrees Celsius Best performance can be obtained at a relative humidit...

Страница 21: ...ions of the on line manual may be printed as desired To access the on line help click on the help button at the bottom of each program screen Customer Support If you need additional help a Cirris Cust...

Страница 22: ...tion is not responsible for special incidental or consequential damages resulting from any breach of warranty or under any other legal theory including lost profits downtime goodwill damage to or repl...

Отзывы: