Table 12 (Continuation): Parameter codes for alarm programming�
Parameter
Code
Parameter
Code
ActivepowerL3
13
PowerfactoryL3
15
Inductive/CapativereactivepowerL3
14
MaximumdemandL3
(1)
43
(1)
Parametervalidonlyifprogrammedthemaximumdemandcurrentperphase�
Inaddition,therearesomeparameters(
Table 13
)thatrefertothethreephasesatthesame
time(ORfunction)�Ifyouhaveselectedoneofthesevariables,thealarmwillbeactivatedwhen
anyofthethreephasesmeetstheprogrammedconditions�
Table 13:Multiple parameter codes for alarm programming�
Parameter
Code
VoltagesPhase-Neutral
90
Currents
91
Activepowers
92
Reactivepowers
93
Powerfactor
94
VoltagesPhase-Phase
95
THDV
96
THDA
97
Onceanalarmcodehasbeenselectedandvalidatedwiththe
keyyoumustenterthe
maximumvalueofthealarmcondition�
The
maximum value
:abovethisvaluethetransistorisclosed�
Toenterormodifythemaximumvalue,pressthe
key
repeatedly,increasingthevalueoftheflashingdigit�
Whentheon-screenvalueisthatdesired,pressthe
keyto
gotothenextdigittomodifytheothervalues�
Ifyoupressthe
keyaftermodifyingthelastdigitthedecimalpointpositionwillbe
programmed�
Tovalidatetheinformationandproceedtoprogrammingtheminimumvalue,press
�
The
minimum value
:belowthisvaluethetransistorisclosed�
Toenter ormodify the minimum value, press the
key
repeatedly,increasingthevalueoftheflashingdigit�
Whentheon-screenvalueisthatdesired,pressthe
keyto
gotothenextdigittomodifytheothervalues�
Ifyoupressthe
keyaftermodifyingthelastdigitthedecimalpointpositionwillbe
programmed�
Tovalidatetheinformationandproceedtoprogrammingthedelayvalue,press
�
35
Instruction Manual
CVM-C5
Содержание CVM-C5-IC
Страница 1: ...INSTRUCTION MANUAL M98252801 03 17A Power analyzer CVM C5 IC CVM C5 MC IC CVM C5 mV IC...
Страница 2: ...2 CVM C5 Instruction Manual...
Страница 42: ...8 CE CERTIFICATE 42 CVM C5 Instruction Manual...
Страница 43: ...43 Instruction Manual CVM C5...