15
5)
Winter Mode
: Reduces the chosen Chlorine Output setting by half,
for periods of low chlorine demand during cool weather.
6)
Select
: While in the Menu, the left/right arrows change options for
Pool Temperature, Instant Salinity, and Cell Version.
7)
Menu
: Press sequentially to cycle through the following information:
1.
Pool Temperature
(xx degrees Fahrenheit or Celsius)
2.
Cell Voltage
(in many cases 21.0 to 27.0 volts when chlorine
is being generated, otherwise 16-31V)
3.
Cell Curren
t (in many cases 2.50 to 7.80 amps when chlorine
is being generated, otherwise 0 amps during normal rest
cycles.)
4.
Real-Time Salinity
reading
( xxxx ppm or x.x grams/Liter.)
5.
System ID
6.
Software revision level
7.
Cell Version.
LED INDICATOR LIGHTS
:
•
Power
: Located on the Power Button, this LED indicates that the
Control Module is receiving input power when illuminated.
SAFETY TIP:
Using the Power Button to turn the system OFF does
not remove power from the control box. Always disconnect power
at the circuit breaker prior to attempting any service procedure.
•
Generate
: This LED is illuminated during normal operation, and
indicates that the system is able to generate chlorine. When flashing,
the pool water is either too hot or too cold for chlorine generation.
This light may be off during rest periods of the system's duty cycle.
•
Super CL
: Located on the Super CL Button, this LED is illuminated
when the Super CL mode has been activated.
•
Winter Mode
: Located on the Winter Mode Button (snow flake icon),
this LED is illuminated when the winter mode has been activated.
Содержание RJ PLUS series