8
CircuPool RJ-Series has been designed to easily wire into typical in-
ground pool systems. To provide safe operation, the unit must be
properly grounded and bonded.
Bonding:
A lug used for bonding is attached to the bottom of the
RJ-
Series
Control Module. The Control Module must be bonded with an 8 AWG
copper wire to the pool bonding system.
Electrolytic Cell and Flow Switch Connections:
The Cell and Flow Switch cables have easy plug-in connectors, which
attach easily to the Control Module. Refer to the diagram below for the
location of these connections.
Wiring to Power Source:
The Control Module comes with an un-terminated Power Cord (AC
Input) which is typically connected to an external timer, which will turn
the pump and Control Module on and off together. Have the Control
Module wired to the load side of the timer by a qualified person. See
the following diagram for typical wiring. See voltage warning on page 9.
The RJ-Series is shipped from the factory with a 240 VAC configuration.
If 120VAC is needed, move the internal jumpers as shown on page 21. If
unsure, seek professional advice.
When used with variable-speed or other electronically controlled
pumps, you may wish to wire the Control Module directly to your power
source. This will allow the pump to determine when the Cell is
energized or dormant by activation of the Flow Switch.