- 5amp/250 volt Slow-Blow glass fuse located inside the unit on the bottom of the power
control board. Found at RadioShack (part #270-1067) or any Auto Parts store. (picture below)
If the glass fuse is bad, it will have a black or grey mark in the middle of the glass portion area of the
fuse. Do not service unless all power has been disconnected.
Replacing the power protection mechanism (WARNING: Make sure all power has been disconnected):
Model-A
- 5amp Reset Breaker
1)
Disconnect the control panel from the black wall mounting bracket.
2)
Unscrew the six screws from the back of the control panel (picture 1, below)
3)
Locate and unscrew the exterior ½ inch hex nut located on the bottom the control unit.
4)
Disconnect the two wires that are attached to the back of the reset breaker.
5)
Reconnect the two wires onto the new breaker (position of wires on the breaker doesn't matter).
6)
Install new breaker making sure that the sticker label faces the right side of the unit. (picture 2,
below)
7)
Screw back on the ½ inch hex nut on the outside of the control panel
8)
Put the front cover back on. IMPORTANT: Make sure the grey ribbon cable does not get
positioned over one of the screw holes
.
Pic. 1, removing screws
Pic. 2, replacing fuse reset breaker