OG_STD-302S-429M_v11e
Circuit Design, Inc.
16
OPERATION GUIDE
PLL FREQUENCY SETTING DATA REFERENCE
429 MHz ISM band (429.1750 – 429.7375 MHz)
No.
Channel
Frequency
FCH
Expect
Frequency
F
EXPECT
Lock
Frequency
FVCO
Number of
Division
n
Programable
Counter
N
Swallow Counter
A
(MHz)
(MHz)
(MHz)
1
429.1750
407.4750
407.4750
32598
509
22
2
429.1875
407.4875
407.4875
32599
509
23
3
429.2000
407.5000
407.5000
32600
509
24
4
429.2125
407.5125
407.5125
32601
509
25
5
429.2250
407.5250
407.5250
32602
509
26
6
429.2375
407.5375
407.5375
32603
509
27
7
429.2500
407.5500
407.5500
32604
509
28
8
429.2625
407.5625
407.5625
32605
509
29
9
429.2750
407.5750
407.5750
32606
509
30
10
429.2875
407.5875
407.5875
32607
509
31
11
429.3000
407.6000
407.6000
32608
509
32
12
429.3125
407.6125
407.6125
32609
509
33
13
429.3250
407.6250
407.6250
32610
509
34
14
429.3375
407.6375
407.6375
32611
509
35
15
429.3500
407.6500
407.6500
32612
509
36
16
429.3625
407.6625
407.6625
32613
509
37
17
429.3750
407.6750
407.6750
32614
509
38
18
429.3875
407.6875
407.6875
32615
509
39
19
429.4000
407.7000
407.7000
32616
509
40
20
429.4125
407.7125
407.7125
32617
509
41
21
429.4250
407.7250
407.7250
32618
509
42
22
429.4375
407.7375
407.7375
32619
509
43
23
429.4500
407.7500
407.7500
32620
509
44
24
429.4625
407.7625
407.7625
32621
509
45
25
429.4750
407.7750
407.7750
32622
509
46
26
429.4875
407.7875
407.7875
32623
509
47
27
429.5000
407.8000
407.8000
32624
509
48
28
429.5125
407.8125
407.8125
32625
509
49
29
429.5250
407.8250
407.8250
32626
509
50
30
429.5375
407.8375
407.8375
32627
509
51
31
429.5500
407.8500
407.8500
32628
509
52
32
429.5625
407.8625
407.8625
32629
509
53
33
429.5750
407.8750
407.8750
32630
509
54
Parameter name
Value
Phase Comparing Frequency
F
comp
[kHz]
12.5
Start Channel Frequency
F
ch
[MHz]
429.1750
Channel Step Frequency [kHz]
12.5
Number of Channel
46
Prescaler
M
64
Parameter name
Value
Reference Frequency
F
osc
[MHz]
21.25
Offset Frequency
F
offset
[MHz]
21.7
: For data input
: Result of calculation
: Fixed value
Parameter name
Value
Reference Counter
R
1700
Programmable Counter
N
Min. Value
509
Programmable Counter
N
Max. Value
510
Swallow Counter
A
Min. Value
0
Swallow Counter
A
Max. Value
63