OG_MU1-RIK_v20e Circuit Design, Inc.
11
OPERATION GUIDE
Initialize the unit to the factory default settings if communication with the MU-1 mounted on the MU1-RS2 is not
possible or if you are uncertain of the internal settings.
How to initialize the MU-1
Turn on the power while pressing the initialize switch. Then turn the power off and on once again to reset the unit to
the default settings. For details, refer to the default values for each command in the MU-1 Operation Guide.
Status after resetting
The values of the main parameters after initializing are as follows.
1. Link related parameters
User ID: UI = 0000, Group ID: GI = 00, Equipment ID: EI = 01, Destination ID: DI = 01, Channel = 0 channel
2. UART related parameters
Baud rate = 19,200 bps, parity = none, stop bit = 1
3. Parameters related to internal operation
Mode = command
3.2 Initializing