background image

 

OG_LMD-400-R-AB_v11e                                                                                                    Circuit Design, Inc. 

OPERATION GUIDE 

 
GENERAL DESCRIPTION & FEATURES 

 

General Description 

The LMD-400-R (438-442 MHz & 458-462 MHz) is a synthesized multi channel transceiver module 
for  use  under  the  EN  300  113  Land  mobile  services.  This  simple,  compact  and  low  power 
transceiver  is  designed  for  embedding  in  user  equipment  and  suitable  for  various  low  power 
industrial telecontrol and telemetry applications requiring high performance and reliability. 
 
All high frequency circuits are enclosed inside a robust housing to provide superior resistance 
against shock and vibration. Using a TCXO as the reference oscillator circuit of the radio component 
ensures high frequency stability in the temperature range from -20 to +60 °C. 
 

The LMD-400-R is the same size and pin-compatible with Circuit Design’s EN 300220 compliant 
license-exempt transceiver model STD-302N-R that has been widely used as a standard transceiver 
for remote control in industrial radio applications. 

FCC Part 90 certified US version is available in 458 - 462.5 MHz. A custom variant in the 400 MHz 
band, with 4 MHz switching range is available for volume orders. 

 

Features 

 

Programmable RF channel with 12.5 kHz channel space 

 

10 mW, GFSK, 4800 bps 

 

Low power operation 3- 5.5V, 52mA/TX, 42mA/RX 

 

High receiver selectivity & blocking 

 

Small size 50 x 30 x 9 mm 

 

Excellent mechanical durability, high vibration & shock resistance

 

 

Wide operation range - 20 to +60 °C 

 

EN 300 113 compliant 

 

Applications 

 

Industrial remote control  

 

Telemetry 

 

Remote monitoring / Security 

 

Data acquisition/ SCADA 

 
 
 
 
 
 
 
 
 
 

Содержание LMD-400-R

Страница 1: ...multi channel transceiver LMD 400 R 438 442 458 462 MHz Operation Guide Version 1 1 Sep 2011 CIRCUIT DESIGN INC 7557 1 Hotaka Azumino Nagano 399 8303 JAPAN Tel 81 0 263 82 1024 Fax 81 0 263 82 1016 e...

Страница 2: ...PIN DESCRIPTION 6 BLOCK DIAGRAM 8 DIMENSIONS 9 PLL IC CONTROL 10 PLL IC control 10 How to calculate the setting values for the PLL register 11 Method of serial data input to the PLL 12 TIMING CHART 1...

Страница 3: ...high frequency stability in the temperature range from 20 to 60 C The LMD 400 R is the same size and pin compatible with Circuit Design s EN 300220 compliant license exempt transceiver model STD 302N...

Страница 4: ...Item MIN TYP MAX Remarks Oscillation type PLL controlled VCO Frequency stability 20 to 60 C ppm 2 5 2 5 Reference frequency at 25 C TX RX switching time ms 15 20 DI DO Channel step kHz 12 5 Data rate...

Страница 5: ...e DO is established may get longer due to the possible frequency drift caused by operation environment changes especially when switching from TX to RX from RX to TX and changing channels Please make s...

Страница 6: ...D and RXSEL to OPEN or 2 8 V RXSEL I RX select terminal GND RXSEL active To enable the receiver circuits connect RXSEL to GND and TXSEL to OPEN or 2 8 V AF O Analogue output terminal There is DC offse...

Страница 7: ...erminal Lock H 2 8 V Unlock L 0 V RSSI O Received Signal Strength Indicator terminal DO O Data output terminal Interface voltage H 2 8V L 0V DI I Data input terminal Interface voltage H 2 8V to Vcc L...

Страница 8: ...OPERATION GUIDE OG_LMD 400 R AB_v11e Circuit Design Inc 8 BLOCK DIAGRAM LMD 400 R 438 442 MHz 458 462 MHz...

Страница 9: ...OPERATION GUIDE OG_LMD 400 R AB_v11e Circuit Design Inc 9 DIMENSIONS...

Страница 10: ...e frequency These signal lines are connected directly to the PLL IC through a 2 k resistor The interface voltage of LMD 400 R is 2 8 V so the control voltage must be the same LMD 400 R comes equipped...

Страница 11: ...note fcomp fosc R Also this PLL IC operates with the following R N A and M relational expressions R fosc fcomp Equation 5 N INT n M Equation 6 A n M x N Equation 7 INT integer portion of a division As...

Страница 12: ...t this phase The PLL IC which operates as shown in the block diagram in the manual shifts the data to the 19 bit shift register and then transfers it to the respective latch counter register by judgin...

Страница 13: ...ssion occurs If the module is switched to the receive mode when operating in the same channel a new PLL setting is not necessary it can receive data within 5 ms of switching 1 For data transmission if...

Страница 14: ...nged 5 ms 4 40 ms CPU Power on CH Data 5 5 ms 5 ms Check LD signal Check LD signal Normal status Status immediately after pow er comes on Channel change No channel change 4 2 Initialize the port conne...

Страница 15: ...875 34919 545 39 458 2000 436 5000 436 5000 34920 545 40 458 2125 436 5125 436 5125 34921 545 41 458 2250 436 5250 436 5250 34922 545 42 458 2375 436 5375 436 5375 34923 545 43 458 2500 436 5500 436 5...

Страница 16: ...34942 545 62 458 4875 436 7875 436 7875 34943 545 63 458 5000 436 8000 436 8000 34944 546 0 458 5125 436 8125 436 8125 34945 546 1 458 5250 436 8250 436 8250 34946 546 2 458 5375 436 8375 436 8375 349...

Страница 17: ...s the LMD 400 R should be mounted on the circuit boards of the final products and must be enclosed in the cases of the final products No surface of the LMD 400 R should be exposed Conformity assessmen...

Страница 18: ...OG_LMD 400 R AB_v11e Circuit Design Inc 18 OPERATION GUIDE Regulatory compliance information...

Страница 19: ...ipment connected to the radio module Communication performance will be affected by the surrounding environment so communication tests should be carried out before actual use Ensure that the power supp...

Страница 20: ..._LMD 400 R AB_v11e Circuit Design Inc 20 OPERATION GUIDE REVISION HISTORY Version Date Description Remark 0 9 Jan 2010 Preliminary 1 0 May 2010 DOC added specification reviewed 1 1 Sept 2011 DOC updat...

Отзывы: