LP
E4
2
02
2.
03
e
n-
G
B
, I
D
-N
o.
: 1
63
-0
41
/E
www.imo.se
20
S.
• Measure the distance between motor shaft
end and the drive hub.
T.
• Remove the drive hub from the electrical motor
with a puller.
B.
• Measure the distance so that it will be the
same as before the dismount.
• Tight the screw 998B as per the tightening
torque table.
• Lock the screw with sealant Loctite as per the
tightening torque table.
C.
• Mount the magnet 005D onto the drive hub
998 by tightening the bolts 006A.
• Lock the bolts with sealant Loctite as per the
tightening torque table.
A.
• Press the drive hub 998 on to the shaft by
means of a suitable stud bolt with a washer
and nut.
Reassembly
D.
• Mount the electrical motor back into the con-
necting frame and tight the bolts 702.
998B