LP
E4
2
02
2.
03
e
n-
G
B
, I
D
-N
o.
: 1
63
-0
41
/E
www.imo.se
17
Dismantling
A.
•
Turn the electricity OFF.
• Close the valves.
11
11
Use appropriate vessels to collect oil
spillage when removing and opening
the pump.
B.
• Loosen the nut 701B with a spanner.
C.
• Pull out the pump in a straight line from the
connecting frame together with the magnetic
coupling. Beware of the magnetic force!
E
.
• Remove the circlip 005A with a suitable plier.
D.
• Loosen the screws 007A with a allen key
• Pull out the sealing can 005B
• Remove the o-ring 007B
F.
• Remove the inner magnetic rotor by means of a
suitable puller.
701B
007A
007B
005B
005A