b.  Sealed ball bearing is assembled to power rotor (63) with a light press fit.  Ball bearing (49) 

may be removed by using a bearing puller or a vertical arbor press. When using press, two 
pieces of key stock are to be placed through openings of mechanical seal seat adapter (48) 
underneath ball bearing (49) on both sides of power rotor shaft.  Key stock should be long 
enough to support power rotor (63) as it is placed in press.  Press ram is to be positioned 
against power rotor (63) coupling end face.  Gently press power rotor (63) through ball 
bearing (49). Ensure power rotor (63) does not fall to floor once ball bearing (49) is off of its 
diameter. 

 
c.  Remove seal seat adapter (48) from power rotor (63), (See seal insert Figure 4) then remove 

stationary seat from seal seat adapter (48).  Loosen set screws on mechanical seal rotating 
assembly body and remove rotating seal seat from power rotor (63).  Remove spacer (38) 
from the power rotor (63).  

 

10. Remove O-ring (80) from inboard end cover (46).  

 

 
11. Remove bolts (4) and inboard cover (46) from case (1).  
 
12. Remove O-ring (28) from inboard cover (46). 
 
13. Remove tube (26) from idler stop (22).  
 
14. Remove idler stop (22) from inboard cover (46) by removing bolts (81).  
 
15. Remove floating balance piston (79) from inboard cover (46).   
 
16. Remove stop pin (6) and Dyna seal (7) from case (1). 

 

17. Remove housing (24) from case (1) and O-ring (28) from housing (24). 

 

18. Remove Orifice Plug (102) from discharge housing (24). 

 

CAUTION

 

ATTENTION

 

Do not permit housing (24) to drop as it is removed from pump. 

 

19. Remove tube (26) from housing (24 or 73), and O-rings (27) from tube (26). 
 
20. Remove aligning vent pins (3) from housing (24 or 73). 
 
21. Remove housing (73) from case (1).  

 

CAUTION

 

ATTENTION

 

Do not permit housing (73) to drop as it is removed from pump. 

 

H.4  PUMP ASSEMBLY PROCEDURE 

 

Note:

 

Prior to reassembly of pump, all parts should be cleaned and inspected for nicks and 
burrs.  Replace all worn or damaged parts.  Imo Pump recommends replacement of all O-
rings (9, 27, 28, and 80), Dyna Seal (7), mechanical seal (25) and ball bearing (49) when 
these parts are disturbed from their previously installed positions.  Coat all parts with light 
lubricating oil to assist in assembly. 

 
Note: 

Bolts (81) have Nylok threads. Torque stated on assembly drawing for bolt (81) does not 
include additional torque to install fasteners containing Nylok inserts. Torque required for 

Содержание IMO 3220/523

Страница 1: ...er BOM 3220 523 WARNING This manual and the General Installation Operation Maintenance and Troubleshooting Manual SRM00046 should be read in their entirety prior to installing operating or servicing t...

Страница 2: ...fect safety for persons Safety instructions where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of the pump and or protect...

Страница 3: ...n applications where equipment furnished by Imo Pump is to become part of processing machinery these instructions should be thoroughly reviewed to ensure proper fit of said equipment into overall plan...

Страница 4: ...Pump regarding K12DHZ 312P pumps refer to pump nameplate this service manual and assembly drawing as instructed below 1 From pump nameplate record the pump model number serial number and manufactured...

Страница 5: ...MINIMUM MAXIMUM LIQUID TEMPERATURE 0 to 275 F 18 to 135 C MAXIMUM INLET PRESSURE 150 psig MAXIMUM DISCHARGE PRESSURE 2200 psig Continuous Duty FILTRATION See General Instruction Manual SRM00046 DRIVE...

Страница 6: ...D NO 242 OR EQUIVALENT THREADLOCKER PRODUCT NO 271 INSTALL CAP SCREW WITH LOCTITE 3 4 HARDENED CIRCULAR WASHER 3 4 REGULAR SPRING LOCKWASHER DETAIL A PP002DA 12 PP002ABH 12 MIN ENGAGEMENT 75 19 1 1 SE...

Страница 7: ...cer 102 1 Orifice Plug X Minor Repair Kit Items XX Major Repair Kit Items Items marked X are included in Major Repair Kit H PUMP MAINTENANCE WARNING Failure to observe precautions while installing ins...

Страница 8: ...ler cups 23 from suction idlers 21 6 Remove suction idlers 21 by unscrewing them from inlet end of pump Remove remaining idlers 35 from housings 73 24 by rotating power rotor 63 in a counter clockwise...

Страница 9: ...d cover 46 13 Remove tube 26 from idler stop 22 14 Remove idler stop 22 from inboard cover 46 by removing bolts 81 15 Remove floating balance piston 79 from inboard cover 46 16 Remove stop pin 6 and D...

Страница 10: ...on inboard cover 46 with cap screws 81 Torque cap screws to value on assembly drawing Install O ring 28 on inboard cover 46 7 Install inboard cover 46 on case 1 using bolts 4 Be sure that tube 26 line...

Страница 11: ...sition disconnect seal piping 71 remove bolts 4 and rotate inlet head to desired position Install bolts 4 and torque to proper values indicated on assembly drawing Reconnect seal piping 71 20 Install...

Страница 12: ...are used to repair leaking seals bad bearings and or for re assembly after pump tear down They include as applicable pump shaft seals packing all gaskets O rings and bearings Major Repair Kits are suf...

Страница 13: ......

Страница 14: ...CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2021 CIRCOR Pumps North America LLC All rights reserved...

Отзывы: