background image

7

7. Finalizing the Fitting Make-up

7.1  

Insert the end with pre-set ferrules and nut into

 

 

the fi tting. Thread and rotate the nut until hand-tight.

 

 

While supporting the fi tting body, tighten the nut

 

 

with a wrench 

1

2

 turn for tubing up to 1” (25mm).

 

 

For tubing greater than 1” (25mm) 

3

4

 turn is required.

 

 

The initial fi tting make-up is now complete.

8. Dismantle & Store Unit

8.1  

Open the Hand pump release valve.

8.2  

Remove the Die and Jig from the Pre-Setting head

 

 

by fi rst unscrewing the Die-Fixing bolt, using the 5mm Hex 

  wrench 

provided.

8.3  

Remove the Die-Fixing bolt and store in a safe place. 

 

 

Unscrew the Jig along with the Die, turning it 

 

 

counter-clockwise, using the wrench provided.

8.4  

Disconnect the hand pump hose from the female 

 

 

coupler on the Pre-Setting head by loosening the coupler collar.

 

 

    

Содержание HOKE 3HPST

Страница 1: ...Continuously Improving Flow Control HOKE 3HPST User Instructions Continuously Improving Flow Control...

Страница 2: ...1 Connect hand pump to Pre Setting head The hand pump is supplied with a hose connected Therefore the free end needs to be connected to the Pre Setting head 1 1 Remove the hand pump and Pre Setting he...

Страница 3: ...the System Bleeding process prior to using the tool and whenever any part of the hydraulic system has been disconnected 2 1 Position the hand pump at a higher elevation than the Pre Setting head this...

Страница 4: ...p the Die and Jig as a matched pair and stored in the black case when not in use 3 1 Select the corresponding Die and Jig set to the desired tube size you wish to pre set Make sure the Die and Jig is...

Страница 5: ...elease position screw the Indicator Nut on to the threaded piston shaft 5 Tube Preparation 5 1 Ensure the tube outside diameter wall thickness and hardness is within acceptable specifications Free fro...

Страница 6: ...hand pump release valve turn clockwise 6 6 Pump the handle until the indicator arm releases CAUTION Stop pumping immediately after the arm releases as over pumping may cause the tube to swell and stic...

Страница 7: ...The initial fitting make up is now complete 8 Dismantle Store Unit 8 1 Open the Hand pump release valve 8 2 Remove the Die and Jig from the Pre Setting head by first unscrewing the Die Fixing bolt us...

Страница 8: ...ive plug removed and stored earlier 8 6 Store clean components and accessories in the black case 8 7 Lay the black case down horizontally when possible during storage PRE SETTING HEAD HAND PUMP HOSE H...

Страница 9: ...with each other to create optimal driving force to seat the ferrules to the tube and create a leak tight connection The installation of used ttings and bodies may cause unintended leakage due to the...

Страница 10: ...registered facility headquartered in Spartanburg SC USA a division of CIRCOR International NYSE CIR HOKE distributors are worldwide Contact us or visit our website to locate the nearest distributor t...