1.3
Remove the protective plug from the inlet connector on the
Pre-Setting head, turn counter-clockwise. Keep the plug in a
safe place, such as in the black case.
1.4
Connect the free end of the hand pump hose to the inlet
connector on the Pre-Setting head tightening the male and
female couplers together.
3
2. System Bleeding (Air Removal)
Perform the System Bleeding process prior to using the tool and
whenever any part of the hydraulic system has been disconnected.
2.1
Position the hand pump at a higher elevation than the
Pre-Setting head; this will help in chasing any trapped air out of
the hydraulic system. (See FIG 1, below)
2.2
Vent hand pump reservoir, by
turning the fi ll cap a 1/4 of a
turn to the “VENT” position and
ensure the hand pump release
valve is closed.
2.3.
Turn release valve handle clockwise. Ensure the vent end of the
Hand Pump reservoir is the highest point in the system.