![Circor 6139-8010 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/circor/6139-8010/6139-8010_installation-and-operating-instructions-manual_2607995017.webp)
Einbau- und Betriebsanleitung
Installation and Operating instructions
Instructions de montage et de service
6139-8010
07/2018
•
The compressed air supply for the valve, drive and other equipment must be shut off.
•
Use a bypass valve or other equipment to avoid a complete system failure
•
Ensure there is no compressed air connected with the drive
4.2 Assembly tools
1 Hexagonal spanner
2 Phillips screwdriver
3 Hex screw spanner
4.3 SR 1000 L assembly
SR 1000 L should be connected to valves with linear movement such as gate- or check valves, moved by pneumatic force.
Be sure to have the following components available prior to assembly.
1 SR 1000 L
2 Lever and spiral spring
3 Retaining plate
4 Guide rail
5 Actuating pin
4.4 Standard parts
1 DIN 933 hexagonal screw M8 x 16 (6x)
2 DIN 125 washer 8 (6x)
3 DIN 933 hexagonal screw M5 x 10 (2x)
4 DIN 125 washer 5 (2x)
5 DIN 7980 lock washer 5 (2x)
4.5 Assembly
10.
Mount the lever with a M5 nut and secure with a round-head screw to prevent turning.
Figure 2 Figure 3
11.
Mount the guide rail to the parallel guide using two M5x10 hexagonal screws and two washers and two lock screws. Place the washers between the
lock washers and the parallel guide. See figure 4