82
Master/Slave Instruction Manual
Value
Description
Metervalue sample
interval
Number of seconds between MeterValue during an ongoing
Charge Transaction.
*NOTE
:
setting this value to 0 disables the MeterValue.
Transaction
message retry
interval
Number of seconds between transaction message attempts.
*NOTE
:
setting this value to 0 disables the attempts.
Charging cable
connection timeout
Number of seconds the Charge Point must wait for the user to
plug/unplug the cable.
*NOTE:
this field is for information purposes, it cannot be
modified.
Local authList
enabled
Yes:
Local Authorization List enabled
No
:
Local Authorization List disabled
Local auth list
max. length
Maximum size of the
Local Authorization List, a list of identifiers
that can be synchronized with the Central System.
It can be viewed accessing to the following URL:
http://<IP>:8080/services/cmd/dump_localList.xml
*NOTE:
this field is for information purposes, it cannot be modified.
Send local list
max. length
Maximum number of identifications that can be send in a single
request from the Central System.
*NOTE:
this field is for information purposes, it cannot be modified.
Reserve connector
zero supported
Yes:
Charge Point supports reservations on connector 0. That
reservervation is not done on a specific connector, one connector
remains available for the reserved idTag.
No
:
Charge Point does NOT support reservations on connector 0.
Содержание Master-Slave
Страница 1: ...Instruction Manual Master Slave ...
Страница 76: ...74 Master Slave Instruction Manual A window will pop up in order to choose the file then click on upload ...
Страница 87: ...85 Monitoring ...
Страница 90: ...88 Master Slave Instruction Manual 11 ...