background image

8

ILLUSTRATED PARTS LIST

Ref.No.

Part. No.

Description

QTY

Remark

1

647284871

Cover

1

2

65431042080

O-Ring

1

3

647252704

Basket

1

4

647284801

Pump Housing

1

5

647252705

Clip

1

6

65431029080

O-Ring

1

7

65221002000

Screw M5*30

8

8

647284802

Pump Cover

1

9b

647272971000 Impeller For CSPPD704

1

9c

647252771000 Impeller For CSPPD705

1

10

65431044080

O-Ring

1

11

65028003000

Seal Assembly

1

12

647284803

Pump Housing

1

13

647284804

Motor Mounting Plate

1

14

65231016106

Nut M5

8

15d

65023404000

Dual Speed 1.0HP Motor For CSPPD704 1

15e

65023405000

Dual Speed 1.5HP Motor For CSPPD705 1

16

65432002080

Drain Plug Gasket

1

17

648860105

Drain Plug

1

18

647202702

Adaptor

1

19

91382005

1.5

’’

Adaptor Assembly

2

Содержание CSPPD704

Страница 1: ...s and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This...

Страница 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Страница 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Страница 4: ...ruction concerning use of the appliance by a person responsible for their safety 16 The pump must be protected from running dry LOCATION The pump must be located as close as practical to the pool The...

Страница 5: ...d on IEC 364 7 702 requirements RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL Electrical Connection Check that the information on the nameplate corresponds to the power supply E...

Страница 6: ...nded in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high At other times switch to low speed For backwashing and vacuuming high sp...

Страница 7: ...d adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical protection devices of the motor and that the protections against el...

Страница 8: ...the case of any excessive high stop immediately and have it repaired CAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual...

Страница 9: ...9b 647272971000 Impeller For CSPPD704 1 9c 647252771000 Impeller For CSPPD705 1 10 65431044080 O Ring 1 11 65028003000 Seal Assembly 1 12 647284803 Pump Housing 1 13 647284804 Motor Mounting Plate 1 1...

Страница 10: ...or controls Faulty Pump shaft motor Replace the pump motor assembly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sur...

Страница 11: ...ncorrect voltage Supply to be corrected by electrician A motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temper...

Страница 12: ......

Отзывы: