8. The operating safety of the pump is only guaranteed if the installation and service
instructions are correctly followed.
9. The limit values stated in the technical table should not be exceeded under any condition.
10. In the event of defective operation or fault, contact the technical support department of the
manufacturer or it

s nearest authorized agents.

11. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person to avoid a hazard.
12. The pump must not be used when people are in the water.
13. The pump must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
14. Children should be under close supervision to prevent them from playing with the pump.
15. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
16. The pump must be protected from running dry.

LOCATION

The pump must be located as close as practical to the pool. The pump must also be in a
position that enables easy access for periodic servicing.
Care must also be taken to position the pump in an area that is free from flooding in a well
ventilated and dry area.

It is recommended that a valve, elbow or tee installed in the suction line should be no closer to
the front of the pump than five (5) times the suction line pipe diameter.

INSTALLATION

A few simple precautions during installations will ensure years of trouble free operation.
1. The pump suction line should not be smaller than 1 1/2" (40mm imperial) or 50mm true
metric.
2. The suction line is to have as few bends or elbows as possible. There must not be an air
traps on the suction line.
3. Installation shall arrange on a solid, flat foundation with the pump bolted securely to it.
4. The pump electrical cable must be wired for the proper voltage and current in accordance
with the wiring instructions.
5. All wiring (electrical) work must be carried out by licensed electricians and must be installed

3

Содержание CSPPD704

Страница 1: ...s and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This...

Страница 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Страница 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Страница 4: ...ruction concerning use of the appliance by a person responsible for their safety 16 The pump must be protected from running dry LOCATION The pump must be located as close as practical to the pool The...

Страница 5: ...d on IEC 364 7 702 requirements RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL Electrical Connection Check that the information on the nameplate corresponds to the power supply E...

Страница 6: ...nded in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high At other times switch to low speed For backwashing and vacuuming high sp...

Страница 7: ...d adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical protection devices of the motor and that the protections against el...

Страница 8: ...the case of any excessive high stop immediately and have it repaired CAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual...

Страница 9: ...9b 647272971000 Impeller For CSPPD704 1 9c 647252771000 Impeller For CSPPD705 1 10 65431044080 O Ring 1 11 65028003000 Seal Assembly 1 12 647284803 Pump Housing 1 13 647284804 Motor Mounting Plate 1 1...

Страница 10: ...or controls Faulty Pump shaft motor Replace the pump motor assembly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sur...

Страница 11: ...ncorrect voltage Supply to be corrected by electrician A motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temper...