background image

in accordance to the local codes.
6. The motor must be grounded.
7. The weight of the plumbings and fittings is to be independently supported and not carried by
the pump.
8. The maximum total head (Hmax) of the pump (in metres) shown on the pump label should
be noted by the installer.
9.The permissible temperature is> 32

#!

0

°

C

"

and < 104

!

40

°

C

"

. The pump should never be

operated outside of these temperatures, or damage may occur.

Important Electrical Notice
The electrical installation is to be done by a licensed electrician.

Each pump requires a circuit breaker to separate the pump from the electrical supply.
The open contact distance of the circuit breaker is to be no less than 3mm
The pump is to be supplied by an isolating transformer, or supplied through a residual current
device (RCD) with a rated residual current not exceeding 30mA.
Check the pumps name plate for the following: Voltage, Amp draw and Cycle.
The power cord, including the ground wire shall have a quality of 245 IEC66 (HO7RN-F) for
models greater than 1kW power input.
For models less than 1kW input the quality shall be of 245 IEC57 (H05RN-F).
All installations must comply with local codes, based on IEC 364-7-702 requirements.

RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL.

Electrical Connection

Check that the information on the nameplate corresponds to the power supply.
Employ a competent electrician to ensure wiring installation is made in accordance with any
local electrical codes. Every motor requires either a fused disconnect switch or a circuit
breaker.
A SINGLE PHASE MOTOR has a built in thermal overload switch.

Priming

The pump will prime and pre-prime providing the filter tank water and there is sufficient supply
from the suction point.
If you lose water from the filter tank it will be necessary to re-fill it before starting.
1. Remove the translucent lid and fill the filter tank with water.
2. Replace the lid ensuring the o-ring is correctly located and start the pump.
After you have done this allow a few minutes (maximum) running for the pump to start
delivering water.

High suction lift or long suction lines will require additional time to prime and can severely
affect the performance of the pump. If the pump does not prime, please repeat step 1 and 2
above. Mechanical seals if running dry can be damaged rapidly and may need to be replaced.
ENSURE that there is always adequate water in the filter tank before you start up. If you are
unable to prime the pump please see the trouble-shooting guide.

4

Содержание CSPPD704

Страница 1: ...s and Ordinances Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This...

Страница 2: ...at the circuit breaker before servicing the pump Failure to do so could result in death or serious injury to service person pool users or others due to electric shock Pumps improperly sized or instal...

Страница 3: ...cured GENERAL SAFETY RULES 1 The products mentioned in this manual are specially designed for the pre filtering and re circulation of water in swimming pools and spas 2 They are designed to work with...

Страница 4: ...ruction concerning use of the appliance by a person responsible for their safety 16 The pump must be protected from running dry LOCATION The pump must be located as close as practical to the pool The...

Страница 5: ...d on IEC 364 7 702 requirements RESPECT THE MINIMUM GAUGE GIVEN IN THE CHART OF THE TECHNICAL MANUAL Electrical Connection Check that the information on the nameplate corresponds to the power supply E...

Страница 6: ...nded in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high At other times switch to low speed For backwashing and vacuuming high sp...

Страница 7: ...d adaptations and supplementary technical rules may be necessary 4 Before starting the pump verify the calibration of the electrical protection devices of the motor and that the protections against el...

Страница 8: ...the case of any excessive high stop immediately and have it repaired CAUTION Owing to the complexity of the cases covered the instructions for installation use and maintenance contained in this manual...

Страница 9: ...9b 647272971000 Impeller For CSPPD704 1 9c 647252771000 Impeller For CSPPD705 1 10 65431044080 O Ring 1 11 65028003000 Seal Assembly 1 12 647284803 Pump Housing 1 13 647284804 Motor Mounting Plate 1 1...

Страница 10: ...or controls Faulty Pump shaft motor Replace the pump motor assembly Pump shaft is locked Check if the pump can be rotated by hand and remove any blockage Pump will not prime Suction air leak Make sur...

Страница 11: ...ncorrect voltage Supply to be corrected by electrician A motor running hot to touch is normal Thermal overload protector will function to turn them off if there is an overload or excessive high temper...

Страница 12: ......