EGS5 Hardware Interface Description
5 Electrical, Reliability and Radio Characteristics
104
EGS5_HD_v02.004
Page 80 of 123
2012-02-09
Confidential / Released
5
Electrical, Reliability and Radio Characteristics
5.1
Absolute Maximum Ratings
The absolute maximum ratings stated in
are stress ratings under any conditions.
Stresses beyond any of these limits will cause permanent damage to EGS5.
The power supply connected to the EGS5 module shall be compliant with the SELV require-
ments defined in EN60950. Above all, the peak current of the power supply shall be limited ac-
cording to
.
Table 20:
Absolute maximum ratings
Parameter
Min
Max
Unit
Peak current of power supply
1.6
A
Supply voltage BATT+
-0.3
4.9
V
Voltage at digital lines in POWER DOWN mode
-0.3
0.3
V
Voltage at digital lines in normal operation
-0.3
3.05
or
VEXT+0.3
V
Voltage at analog lines in POWER DOWN mode
-0.3
0.3
V
Voltage at analog lines, VMIC on
1
1.
For normal operation the voltage at analog
line
s with
VMIC on
should be within the range of 0V to 2.4V
and with
VMIC off
within the range of -0.25V to 0.25V.
-0.3
3.0
V
Voltage at analog lines, VMIC off
-0.3
0.3
V
Voltage at VCHARGE line
-0.3
7.0
V
Voltage at CHARGEGATE line
-0.3
7.0
V
VUSB_IN
-0.3
5.5
V
USB_DP, USB_DN
-0.3
3.5
V
VSENSE
5.5
V
ISENSE
5.5
V
PWR_IND
-0.3
10
V
VDDLP
-0.3
5.5
V