background image

 

10

 

Batch Scanning

 

Thanks to the Batch Scanning function, the scanner is capable of storing all 
input  data into memory  storage.  It is  an ideal cost-effective  solution to fulfill 
most inventory applications. 
 

Configure Batch Scanning Options 

Before  you  start  to  use  batch  scanning,  please  enter  “

SETUP

”  then  select 

Batch Scanning

” to configure  all  available options listed  below.  Moreover, 

the  “Auto  Save”  and  “Auto  Delete”  functions  will  help  you  to  simplify  the 
routine operation of data collecting. 

 

Input Fields 

Besides the field of “

Item No.

”, three more input fields are available for choice, 

including  “

Quantity

”,  “

Location

”  and

  “Timestamp

”.  By  default,  both  “Item 

No.”  and  “Quantity”  fields  are  enabled.  Please  note  that  if  you  changed  the 
composition of input fields, all stored data will be 

DELETED

 

Validation 

You  can  set  the  desired  input  range  of  each  field.  The  scanner  will  do  the 
validation automatically after the inputs of each field are completed. 

 

Field and Record Delimiters 

Both  field  delimiter  and  record  delimiter  can  be  changed  to  meet  your 
application demand. 

 

Transmission Sequence 

The  transmission  sequence  of  each  field  can  be  re-arranged  to  meet  your 
needs. 

 

Transmission Interface 

The scanner is preset to transmit all stored data through 

Wi-Fi

. Alternatively, 

you can transmit the stored data through physical USB interface by changing 
the transmission interface to USB COM or USB HID. In this case, a charging 
cradle has to be used together with your scanner. 

 

Auto Save   

After completing the inputs of each record, the scanner will save the data into 
storage  automatically  then  go  to  next  record  input  immediately.  You  do  not 
need  to  press  “

Save

”  (L  Key)  to  save  data.  If  you  still  prefer  to  save  data 

manually, please disable this Auto Save function. 

 

Auto Delete 

The scanner is preset to keep all stored data after data transmission in case it 
needs  to  be  retrieved  later.  You  have  to  delete  all  records  manually.  If  you 
prefer  the  scanner  to  perform  “Auto  Delete”  after  data  transmission,  please 
enable this function. 

 

Link Control 

For  power saving,  the Radio can  be disabled during  batch  scanning. When 
you  want  to  transmit  the  data  via Wi-Fi,  the  scanner  will  activate  the  Radio 
and re-connect automatically. 

Содержание FuzzyScan F790WD

Страница 1: ......

Страница 2: ...onnectivity with true business value This document provides an easy reference for installation and operation purpose For more reference material please visit our web site for details F790WD L780WD Ser...

Страница 3: ...ttery contacts of the battery pack are facing the charging contacts inside the battery cavity Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end...

Страница 4: ...nner You will need following information for wireless network setting before creating a new profile SSID The SSID is an 802 11 service set identifier of Independent Wireless Host or Access Point AP Op...

Страница 5: ...ally You will hear power on beeps and the Date setup screen will be displayed after the welcome message Use the virtual keyboard to complete the date information input then press Enter L key to save t...

Страница 6: ...Signal Strength Time Battery Status Link Status Title Connecting to the server Disconnected Almost no signal Very low signal Low signal Medium signal Good signal Low battery Battery is 20 full Battery...

Страница 7: ...and Output Interface Settings In Interface Setting you can define the detailed working behaviors of Wi Fi USB COM and USB HID Online Scanning In this setting you can configure all available options o...

Страница 8: ...port number to meet your WLAN setting Ensure the scanner is activated within radio range then enter SETUP from the Desktop main menu Select Wi Fi Profiles then press New L key to add a Wi Fi Profile...

Страница 9: ...r application to work with multiple scanners HID Conversion To enable this feature please select the HID check box By doing so all incoming data from that scanner will be converted as HID keyboard inp...

Страница 10: ...og storage is full If necessary you can enter this to view all scan logs Host Acknowledgement For more Reliable Data Transfer the useful Host Acknowledgement function provides a helpful handshaking pr...

Страница 11: ...elimiter can be changed to meet your application demand Transmission Sequence The transmission sequence of each field can be re arranged to meet your needs Transmission Interface The scanner is preset...

Страница 12: ...ored data through Wi Fi During the transmission process the scanner will give continuous short clicks and blue blinks Then the scanner will give two short beeps after data transmission is completed If...

Страница 13: ...ght screen It s very helpful for locating link problem if you have difficulty to make a successful link Data Validation The Data Validation is a very useful tool for you to check valid input with ease...

Страница 14: ...WaveCentre together with your Wi Fi scanner you can easily use all remote control functions without writing a program If you want to use the remote control in your application please contact your sup...

Страница 15: ...harged on cradle 1 green blink at regular interval Off Out of memory 2 red blinks 2 long beeps Battery power low 1 red blink at regular interval 30sec 1 beep at regular interval 30sec Battery power ex...

Страница 16: ......

Отзывы: