To link to a new transmitter, make sure the fixture is unlinked, in DMX mode and the DMX addresses are
set.
If the unit is in DMX Mode and no cable is inserted in the DMX IN port, Wireless DMX is automatically
activated and the unit can now be controlled on a linked wireless DMX network. When the unit is ready
to receive a signal from a transmitter but is not yet linked, the CONTROL screen will flash “DMX NONE.”
Once the connection is made the CONTROL Screen will change to “DMX WIFI” and can now be control
remotely.
Refer to your wireless DMX transmitter instructions for linking fixtures to a wireless network.
Third party wireless products can be used by plugging the third party wireless antenna into the DMX XLR
port. If power is needed for the antenna the powered USB port can provide such up to 500ma@ 5VDC. If
a third party wireless device, powered or non powered, is attached via the 5pin XLR port this connection
will take priority over the imbedded wireless receiver.
RDM Support
The fixture supports RDM Discovery and Identify commands for identifying fixtures on the network.
The Standard 410 supports both GET and SET commands remotely through an RDM controller. The
GET information provided includes the Unit ID, device type, firmware revision, DMX address and DMX
Personality.
The unit supports SET Commands to allow remote programming of the following:
LOCAL / DMX Personality
DMX base address
Calibration
To perform a remote Calibration, follow these steps:
1. Select device to be calibrated with the RDM controller
2. Select DEVICE STATE from the RDM menu
3. Within the DEVICE STATE menu, select MORE
4. Choose SET FACTORY DEFAULT
5. Execute the command
USB Port
An A-type USB port is included on the control panel for installation of software updates. It can also
supply 5 VDC, 500ma power to attached devices. Refer to installation instructions supplied with software
upgrade.
Mounting Options
The Standard 410 has a fully rotational yoke with a TVMP mount. The standard yoke can be removed, and
an optional Pole-Op yoke can be attached.