![Cineo Standard 410 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cineo/standard-410/standard-410_user-manual_2607449013.webp)
13
Calibration
The Standard 410 should periodically be calibrated to re-
align all controls to their proper settings. When CALIBRATE is
highlighted on the menu and selected with the large knob
push, the fixture will perform a self-calibration routine, lasting
approximately one minute and then returning to its previous
operating status.
Factory Reset
This menu option is designed primary for rental facilities. In one step, it performs a CALIBRATE, clears all
presets, UNLINKs the Radio and returns the unit to LOCAL Mode, with all values set at 0.
Connections
Wired DMX Connections
Standard 410 uses industry-standard 5-Pin XLR male and female connectors to receive and forward DMX
signals and output RDM signals. The DMX port is self-terminating and does not require external DMX
termination when used in a chain. If the unit is the last device on a DMX chain, make sure that there is no
cable inserted into the DMX Out connector.
The DMX pin wiring is as follows:
• Pin 1: Signal Common
• Pin 2: Data –
• Pin 3: Data +
• Pin 4: Spare
• Pin 5: Spare
Wireless DMX Control
The Standard 410 built-in wireless receiver runs on CRMX / Lumen Radio protocol which can receive
signals from CRMX and some WDMX transmitters. Please note that each fixture can only be linked to a
single transmitter at a time, and maintains the transmitter ID of its previous linking. Therefore, the fixture’s
linking data must be cleared prior to linking to a new network, using the Unlink Radio function.