2.5 INSTALLING THE CINDERELLA INCINERATING TOILET
It is essential to ensure proper ventilation in accordance with the guidelines in this manual to guarantee the
functionality of your new Cinderella toilet. Improper installation may cause malfunction, wear or odors and will
void the warranty. Read each section carefully before starting the installation of the toilet. Always make sure that
the work is carried out by professionals in accordance with local regulations.
WARNING!
Before cutting any holes, always check that you will not cut any electrical wiring or water
pipes.
CAUTION!
• Upon installation of the appliance, the technical and administrative regulations of the
country in which the toilet is installed must be adhered to. We recommend that you
contact your local dealer for planning and installing your Cinderella toilet.
• Never use any bends in addition to the elbow bend.
• If the pipe perforates the roof surface, ensure that it is in compliance with
building regulations.
•
Do not use any flexible ducts or pipes when installing the Cinderella toilet.
• Never connect more than one appliance to the vent.
• The elbow must be accessible when installed, so as to be able to rinse the drainage pipe
and clean the outlet pipe regularly,
NOTE!
• During installation of the appliance, the technical and administrative regulations of the
country in which the toilet is installed must be adhered to. We recommend that you
contact your local retailer to plan and install your Cinderella Comfort appliance.
• The inside of the ventilation pipe must be smooth and not embossed or grooved.
• The elbow must be accessible when installed, so that the drainage pipe can be rinsed,
and the outlet pipe cleaned.
•
Cinderella Comfort is proved for use in bathrooms/wet rooms (IP 34 classified), but
water must not be splashed over the external parts of the toilet.
•
The toilet must be placed on a firm and level base and your Cinderella appliance may
be installed on a heated floor
CAUTION!
The Cinderella Comfort toilet must have its own outlet air pipe and it is not permitted to
install Cinderella Comfort ventilation with the use of the following:
• Wind fan or similar as a replacement for the chimney cap
•
Flexible ducts or pipes.
• Pipes with inner diameter less than 95 mm (3 3/4”) .
•
Never use a fine mesh net in the ventilation pipe as this might restrict the airflow in the
system.
Elbow (Outlet air)
Cinderella Comfort is required to be installed with a smooth curved elbow that minimizes
the restriction of the air flow. We strongly recommend using the Original Cinderella Elbow
87° w/ drain. Consult your nearest Cinderella dealer if you consider using any other bend
for this appliance, as any restriction in airflow can cause system malfunction.
Flue Terminal Cap You must install a chimney cap on top of the outlet pipe for your Cinderella Comfort
appliance. We recommend that you use the supplied chimney cap when installing your
system. If you need to use another chimney cap, make sure you consult your nearest
Cinderella dealer. Too much restriction in the chimney cap could cause the system to
malfunction.