ENGLISH
11
2.5.3 INSTALLING THE ORIGINAL CINDERELLA FLUE TERMINAL CAP
NOTE!
The Cinderella Original installation Kit includes a flue terminal cap that is designed for
optimal flow and increased product efficiency. This cap consists of two parts, where the
base section can be fixed to the pipes with stainless screws or glue, this for easy connection
and removal for maintenance of the ventilation pipes. Use the socket-less part of the cut
pipe from when installing the horizontal flue pipe in the Cinderella installation kit as the last
section of the ventilation pipe, this will be utilized as the connection to the flue terminal cap.
M
in
10
m
m
2 x
Min 10mm
25/64”
Power requirements
INPUT
CURRENT
FUSE
220V-240V AC
10 A
10 A
Power consumption
STANDBY MODE
INCINERATING MODE
0.5 W
2000 W
Connection polarity
CABLE CROSS SECTION
PLUG TYPE
14 AWG
NEMA 6-15P
2.6 ELECTRICAL SPECIFICATIONS AND REQUIREMENTS
WARNING!
• This appliance must be installed in accordance with National Electrical Codes, as well
as all state, municipal and local codes.
• The correct voltage, frequency and amperage must be supplied to the appliance from
a dedicated, grounded circuit which is protected by a properly sized circuit breaker.
• The proper voltage, frequency and amperage are listed in this manual and on the
product rating plate on the back of the toilet.
DANGER!
• The connection cable must be laid in such a way that it does not come into contact with
sharp edges.
• Changes to the internal electrical installation or the connection cable must be performed
by a professional tradesman or a similarly qualified person in order to prevent safety
hazards.
• Power converters are not recommended for use with your Cinderella product. Cinderella
comfort has a maximum power consumption level of 2000W, which may be sustained
over periods exceeding an hour at a time. Power converters with a “peak consumption”
level of 2000W may be unable to maintain this power output and become overloaded,
damaged or unsafe if used with your Cinderella Comfort.
NOTE!
The toilet is delivered with a 15 Amp, 250Volt,
2 Pole 3Wire Grounding NEMA6-15P plug. To supply
sufficient power to the unit as delivered, it will re
-
quire a dedicated grounded circuit, with at least 10
amps of available power at 230 V AC.