5
English – User Manual Cinderella Classic
All safety instructions in this manual are marked
with this symbol. Please be sure to pay close
attention to all instructions given in this manual,
especially when you see this symbol.
Note: Energy consumption per incineration will vary between
0.8
–
2.0 kWh, depending on the quantity of waste and use.
The Cinderella Classic incineration toilet is designed to incinerate human feces, urine, tampons, and
toilet paper only.
Using Cinderella Classic to burn other items constitutes misuse and will void your warranty.
Misuse may also cause damage to the toilet or your property and could harm you or those around you.
WARNING:
Do not operate your Cinderella Classic until
you have thoroughly read and you completely
understand all instructions and safety rules
described in this manual. Save this manual and
review it frequently to ensure continuing safe
operation, and for instructing any other users.
Technical specifications
Seated height
21 1/4 in. /540 mm
Height
23 5/8 in. /600 mm
Width
15 3/8 in. /390 mm
Depth
23 1/4 in. /590 mm
Weight
75 lbs / 34 kg
Capacity
3–4 deposits/hour
Ventilation pipe, plastic
4 5/16 in. (110 mm)
Ventilation fan
12 VDC, (Noise: 51 dB)
Voltage
220–240 VAC, 10 Amp
Power consumption (incinerating): Max 2000 W
READ ALL INSTRUCTIONS CAREFULLY
To avoid shock hazard:
1. Always unplug your Cinderella Classic before performing any electrical maintenance.
2. Do not operate the toilet if the cord is damaged or you suspect an electrical malfunction.
To avoid burn hazard:
1. Do not remove the ash container until the toilet has cooled completely.
2. Young children must be supervised when they use Cinderella incineration toilets.
3. Do not install the toilet in an explosive atmosphere.
4. Never burn trash or garbage in Cinderella incineration toilets as it may damage the toilet or cause injury.
Electrical Information
The Cinderella Classic is designed to operate on a 240VAC circuit and a minimum of 10 amps.
It is delivered with a 15 amp NEMA 6-15 plug and chord.
If you do not have the appropriate receptacle available, please contact a licensed electrician to assist with your installation.
For more detailed information, please see the Cinderella Classic Installation Manual.
IMPORTANT NOTE:
Extension cords should not be used
with this appliance.
15 AMPERE-250 VOLT (NEMA 6-15P) PLUG
IMPORTANT NOTE
: When installing this product, be sure to follow all national electrical code regulations.
Remember that there can also be special regional, local and municipal codes and ordinances for your area.