5.1.1.7
DIO I/O Port Address (Default Address 0xA00)
5.2 GM-1000 DIO Hardware Specification
⚫
XCOM+: Isolated power in V+
⚫
XCOM-: Isolated power in V-
⚫
Isolated power in DC voltage: 9~30V
⚫
8x Digital Input (Source Type)
⚫
Input Signal Voltage Level
-
Signal Logic 0: XCOM+ = 9V,
Signal Low
-
V-
< 1V
XCOM+ > 9V,
V+
-
Signal Low
> 8V
-
Signal Logic 1: >
XCOM+
-
3V
⚫
Input Driving Sink Current:
-
Minimal: 1 mA
-
Normal: 5 mA
⚫
8x Digital Output (Open Drain)
-
DO Signal have to pull up resistor to XCOM+ for external device, the
resistance will affect the pull up current
-
Signal High Level: Pull up resistor to XCOM+
-
Signal Low Level: = XCOM-
-
Sink Current: 1A (Max)