background image

 

Ou
tp

ut 

ch

ara

cteristics

 

Output fiber core diameter 

(

μ

m

 

20 

100 

 

Output fiber length 

(m) 

 

15 

 

Customizable

 

Output cable bending radius 

(mm) 

200 

 

 

 

Work model 

 

Continuous/modulation

 

CW/Modulate 

State of polarization 

 

Random

 

Random 

El

ec

tri

ca

l c

oo

li

ng

 c

ha

ra

cteristics

 

Communication interface 

 

RS232 / AD / Super terminal 

 

Remote communication 

 

APP 

Customizable

 

Power supply 

(V) 

 

220 

 

 

Power 
consumption

 

CYL-500/S 

(KW) 

 

 

2.0 

Single phase three

 

CYL-1000/S 

 

 

3.0 

CYL-1500/S 

 

 

4.5 

CYL-2000/S 

 

 

6.0 

220V in two groups

 

CYL-3000/S 

 

 

8.5 

Cooling mode 

 

Water cooling

 

External

 

Cooling water temperature 

(

°C

20 

 

28 

 

Cooling 
water flow

       

CYL-500/S 

(L/min) 

 

 

 

 

CYL-1000/S 

 

10 

 

 

CYL-1500/S 

 

20 

 

 

CYL-2000/S 

 

25 

 

 

CYL-3000/S 

 

 

40 

 

 

Ge
ne

ra

l c

ha

ra

cteristics

 

Working ambient temperature 

(

°C

10 

 

40 

 

Working 

environment 

humidity 

(%) 

10 

 

85 

 

Storage temperature 

(

°C

-10 

 

60 

 

Structure 

 

Rack

 

Weight/ 
Size 

CYL-500/S 

(kg) 

35 

(W) × (L)(

with 

Handle

 

× (H)

 

         

(mm) 

482.6 (

440)×451×104

 

CYL-1000/S 

38 

482.6 

(440)×451×104

 

CYL-1500/S 

40 

482.6 

(440)×451×104

 

CYL-2000/S 

43.4 

482.6 

(440)×596×111

 

CYL-3000/S 

53 

482.6 

(440)×666×111

 

 

2.5 Order information 

 

Содержание CYL-1500/S

Страница 1: ...1 ZHEJIANG CINA LASER TECH CO LTD CYL 1500 S 1 0μm Single Mode Continuous Fiber Laser User manual ...

Страница 2: ...bility and applicability Moreover CINALASER will not be liable for any patent infringement or damage to the rights and interests of any third party caused by the use of this manual CINA LASER will not be responsible for any error information in this manual CINA LASER is not liable for any accidental or indirect consequences arising from the provision execution or use of this manual Direct or indir...

Страница 3: ... 8 3 3 Operating environment 8 3 4 Product performance 9 3 5 Notes 10 3 6 Installation dimensions 10 3 7 Installation notes 10 3 8 Precautions for the cooling system 11 4 0 Use of Products 12 4 1 Front panel of the product 12 4 2 Rear panel of the product 13 4 3 Control interface definition 13 4 4 Power connection 15 4 5 Start operating procedures 16 4 6 Control Mode Selection 16 4 6 1 External co...

Страница 4: ... the following WARNINGs and CAUTIONs and other information contained in this manual WARNING when using this product please make sure to use the appropriate grounding power WARNING the user is not allowed to open any part inside the product for maintenance If necessary please contact CINA LASER technicians to provide maintenance services Any unauthorized changes to this product will result in the w...

Страница 5: ...it is in the state of light 1 3 Optical security If there is dust on the lens of the laser output head the crystal of the laser output head will be damaged or the laser will cause irreparable damage CAUTION do not output the laser without the laser output head protection cap removed otherwise the laser output lens or crystal will burn down 1 4 Electrical security 1 Ensure the product ground wire i...

Страница 6: ...stomization and good after sales service which is an ideal choice for system integrators and equipment manufacturers 2 2 Product advantage High electro optic conversion efficiency greatly reduces power consumption cost Strong anti high reflective ability suitable for processing different materials Remote real time monitoring Long service life high safety and reliability Personalized customization ...

Страница 7: ... three CYL 1000 S 3 0 CYL 1500 S 4 5 CYL 2000 S 6 0 220V in two groups CYL 3000 S 8 5 Cooling mode Water cooling External Cooling water temperature C 20 28 Cooling water flow CYL 500 S L min 8 CYL 1000 S 10 CYL 1500 S 20 CYL 2000 S 25 CYL 3000 S 40 General characteristics Working ambient temperature C 10 40 Working environment humidity 10 85 Storage temperature C 10 60 Structure Rack Weight Size C...

Страница 8: ... to it do not twist bend pull the laser output cable and avoid the collision and vibration of the laser output head CAUTION laser output cable is a precise optical device twisting or overbending the output cable vibration and impact of the laser output head will cause irreparable damage to the laser 3 3 Operating environment Supply voltage V AC 220V 10 50 60Hz Power supply capacity KW Less than 5 ...

Страница 9: ...ed Central wavelength nm 1080 Optical output characteristics of QBH output heads Numerical aperture NA 0 22 Fiber Core Diameter μm 50 customizable Output fiber length m 8 15 customizable Electrical characteristics Working voltage AC 220V 10 50 60HZ Other characteristics Size W L H mm 482 6 440 451 104 Operating ambient temperature range 10 40 Operating ambient humidity range 30 70 Storage temperat...

Страница 10: ...y warranty 3 6 Installation dimensions Figure 1 Laser dimensions unit mm Figure 2 QBH Output head unit mm 3 7 Installation notes 1 Placing the laser horizontally in an appropriate position and fixing it as necessary 2 Please check whether the AC power supply of the laser is at the appropriate voltage 220V AC 10 Single phase three 50 60Hz and whether the grounding wire is good before the laser is p...

Страница 11: ...ng system summer 25 1 winter 24 1 Cooling system requirements 1 Purified water is used for cooling water It is recommended to use purified drinking water 2 To prevent mold growth in the chiller from clogging the pipe it is recommended to add ethanol when filling the purified water The amount of ethanol should be 10 of the purified water 3 When the ambient temperature of the equipment is 10 0 ethan...

Страница 12: ...PH values and solid particle size Long term vibration less than 2G impact less than 10G CAUTION correctly set the water temperature of the cooling system according to the ambient temperature Setting the water temperature too high will lead to the laser cannot work properly setting the water temperature too low will lead to condensed water to be generated inside the laser or in the laser output cab...

Страница 13: ... power input socket must be used with the plug provided by CINA LASER This socket has a lock SERVICE these service connectors provide control signals DB25 connector I O DB15 connector RS232 communications LAN users can set control modes input analog voltage signals modulate 24V signals and are also alarm signal output connectors RS 232 Serial Port Introduction Each pin is defined as follows 4 3 Co...

Страница 14: ... signal does not exceed 10 5V otherwise the laser may be damaged Control signal line All the control signals of the laser are concentrated on the control signal DB25 interface port of the rear panel The diagram on the right shows the control signal line provided by our company CAUTION please check the level of the control signal to make sure it meets the requirement Voltage excess or voltage fluct...

Страница 15: ...on is correct before the laser is powered on Power outlet The other end of the power supply is a stripped three strand wire which marks as L1 N and PE It can be connected to 220V AC power supply according to the wire mark The power cord must be reliably connected as shown in the table before the laser is powered on power line connection Depending on the power of the laser CINA LASER below 2KW usin...

Страница 16: ...y and all the indicator lights on the panel are off The laser enters the on going state 4 6 Control Mode Selection 4 6 1 External control mode daily use status 1 Turn the key switch to ON 2 Wait for the completion of the laser self test about 10s the front panel POWER indicator light is always on 3 Connect to the corresponding interface of the machine s external controller via the DB25 signal cabl...

Страница 17: ...e USB interface on the PC 3 When the laser is powered on press the Power switch button on the rear panel and the green light of the button is always on 4 Double click CINA LASER Fiber Laser Control System Open the software after installation as shown in the following figure 5 Click Refresh select the corresponding port and Open ...

Страница 18: ...lled you can install this collection with one click no need to network the installation must be run as administrator no need to click any dialog box just wait patiently the installation will be completed after reboot support Windows 7 SP1 and later systems compatible with 32 bit and 64 bit The runtime library may be reported by some antivirus software we recommend that you close the antivirus soft...

Страница 19: ...al updates available on Windows Update to ensure optimal compatibility and security NET Framework supports WOW64 32 bit processing on a 64 bit computer and native 64 bit processing on 64 bit operating systems NET options NET that comes with the system does not need to be installed again lower versions of NET are recommended to upgrade the latest version of the runtime library directly generally th...

Страница 20: ...r incorrect operation beyond the limits of product parameters 4 Abuse negligence accident loss or damage during transportation The technical guidance and service provided by CINA LASER to customers will not affect the warranty terms provided by CINA LASER 5 2 Services and maintenance CAUTION there are no built in parts for user maintenance All maintenance shall be carried out by CINA LASER personn...

Отзывы: