18
Operating the X2 Continued...
During operation
1) Once the engine has warmed up (3 to 5 minutes), open the air valve (handle paral-
lel to the line) and begin work.
2) As work progresses, the truck can be slowly moved (10 MPH or less) as required.
CAUTION! NEVER
exceed 10 MPH with the boom extended. To prevent
injury or equipment damage,
ALWAYS
latch and pin the boom backwards when
heighten speeds are required.
NOTICE:
Excessive bumps and potholes should be approached cautious-
ly when the boom is extended.
NOTICE
: It is best practice to shut down the compressor anytime speeds
exceeds 10 MPH.
Shutting Down
WARNING!
The compressor will be extremely hot from operation. Use care
when shutting it down and working around it to avoid severe burns. Personal
Protective Equipment (PPE) such as heat proof gloves are recommended.
1) With the vehicle parked and emergency break engaged, close the air valve on the
compressor.
2) Allow the compressor to run an additional 3 to 5 minutes to cool down, before turn-
ing key to off.
3) Climb up into the vehicle and pull the latch back to release the boom from the for-
ward position and rotate the boom until it latches in the back position.
4) Once in the back position, lift the boom onto the rest and pin it into place.
5) Remove air hose from boom if desired.
6) Open the air valve and all down stream valves to release system pressure. Once
the system has been fully blead, close all valves.