OXE DIESEL SINGLE CONTROL HEAD MANUAL
STATION SELECTION AND STATION SELECT
PROTECTION
The way in which you activate a control station depends on whether the Station
Select Protection (SSP) feature has been enabled. SSP prevents unauthorized or
inadvertent activation of a control head and can only be enabled by an authorized
dealer. By default, SSP is not enabled.
SSP Not Enabled (Default)
On single station boats the control head is always active when the ignition is on,
but on multi-station boats the control head must be activated. This can be done in
two ways:
-
The Smart Select feature will automatically activate a control head if the
levers are moved out of the neutral position. This feature only works when
the ignition is first turned on.
-
The OXE Diesel Control Head can be manually activated using the
SEL
button
with the lever in neutral.
An active OXE Diesel Control Head is indicated by an LED lamp: solid.
SSP Enabled
When SSP is enabled there is no automatic activation of the control head. A
specific sequence of button presses is always required to activate the single lever
control head.
1.
Press
SEL
twice.
2.
Press
N
once.
3.
Press
SEL
again.
-
If the light turns on solid the station is active.
-
If the light flashes, match the lever position with the originally active station
and the light will go solid to indicate that the transfer has been completed.
!
WARNING
Until the light is on solid, the original active station retains control of the shift
and throttle.
CONTROL HEAD OPERATION