SERVICE MANUAL
180
SERVICE MANUAL
180
0-5461 3-1 INSTALLATION
SECTION 3:
INSTALLATION
3.04 Mains Supply Voltage
Requirements
The Mains supply voltage should be within ± 10% of
the rated Mains supply voltage. If actual Mains Supply
Voltage is outside this range Welding Current may
not be available and may cause internal components
to fail.
Refer to Specifications on page 2-5 for Supply Volt-
age information.
The Welding Power Source must be:
• Correctly installed, if necessary, by a qualified
electrician.
• Correctly earthed (electrically) in accordance
with local regulations.
• Connected to the correct size power point and
fuse as per the Specifications on page 2-5.
IMPORTANT NOTE!
This product has been fitted with a supply
plug as indicated in Section 2.10. Note that the
welding output range applicable with the fitted
supply plug is detailed in Section 2.10.
!
WARNING
Any electrical work must be carried out by a
qualified Electrical Tradesperson.
3.05 Generators
Refer to Note 4 on page 2-6 for recommendations
when using with a Generator.
3.01 Environment
These units are designed for use in environments with
increased hazard of electric shock.
A. Examples of environments with increased hazard
of electric shock are:
1. In locations in which freedom of movement
is restricted, so that the operator is forced
to perform the work in a cramped (kneeling,
sitting or lying) position with physical contact
with conductive parts.
2. In locations which are fully or partially limited
by conductive elements, and in which there
is a high risk of unavoidable or accidental
contact by the operator.
B. Environments with increased hazard of electric
shock do not include places where electrically conduc-
tive parts in the near vicinity of the operator, which
can cause increased hazard, have been insulated.
3.02 Location
Be sure to locate the welder according to the follow-
ing guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 0° C to 40° C.
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or
shock.
E. In areas, not exposed to direct sunlight or rain.
F. Place at a distance of 300mm or more from walls
or similar that could restrict natural air flow for
cooling.
3.03 Ventilation
Since the inhalation of welding fumes can be harmful,
ensure that the welding area is effectively ventilated.
Содержание WELDSKILL 180
Страница 20: ...SERVICE MANUAL 180 INTRODUCTION 2 8 0 5461 This Page Intentionally Blank ...
Страница 24: ...SERVICE MANUAL 180 INSTALLATION 3 4 0 5461 This Page Intentionally Blank ...
Страница 28: ...SERVICE MANUAL 180 OPERATION 4 4 0 5461 This Page Intentionally Blank ...
Страница 54: ...SERVICE MANUAL 180 ROUTINE SERVICE REQUIREMENTS 7 4 0 5461 This Page Intentionally Blank ...
Страница 56: ...THEORY OF OPERATION 8 2 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Страница 64: ...PRELIMINARY TROUBLESHOOTING POWER SOURCE 10 6 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Страница 76: ...KEY SPARE PARTS 13 2 Manual 0 5461 SERVICE MANUAL 180 This Page Intentionally Blank ...
Страница 79: ...SERVICE MANUAL 180 This Page Intentionally Blank ...