10-10
January 17, 2008
TRANSTIG 200 AC/DC
SERVICE MANUAL
10.04 Power Source Error Codes (con't)
Remarks
6 E14 error code
displayed.
Under mains
supply (input)
voltage warning
primary
capacitors is
reduced for one
second.
Mains supply voltage is
less than the nominal
operating voltage plus
10%.
Have an Accredited
Cigweld Service Provider
or a qualified electrician
check the Mains voltage.
Weld current
available. Buzzer
sounds
intermittently. Error
code E14 will
automatically reset
when the voltage
increases.
7 E81 error code
displayed.
Wrong Primary
supply (input)
voltage
connected.
When 3 phase machine
is first turned on with
the wrong Primary
supply (input) voltage
connected.
Have an Accredited
Cigweld Service Provider
check the Mains voltage.
No weld current is
available. Buzzer
sounds constantly.
Switch machine off.
8 E82 error code
displayed.
Link switch plug
not connected.
Link switch plug not
connected.
Have an Accredited
Cigweld Service Provider
or a qualified electrician
check the connector plug
on input PCB.
No weld current is
available. Buzzer
sounds constantly.
Switch machine off.
9 E83 error code
displayed.
CPU checks
mains supply
(input) voltage
when the on/off
switch on rear
panel of machine
is turned ON.
The Primary supply
(input) voltage
fluctuates and is not
stable.
Have an Accredited
Cigweld Service Provider
or a qualified electrician
check the connector plug
on the input PCB and the
Mains voltage.
No weld current is
available. Buzzer
sounds constantly.
Switch machine off
then on to reset
E83 error.
10 E93 error code
displayed.
Memory chip
(EEPROM) on
control PCB can
not read/write
weld parameters.
Memory chip (EEPROM)
error.
Have an Accredited
Cigweld Service Provider
or a qualified electrician
check the control PCB.
Weld current is
ceases. Buzzer
sounds constantly.
Switch machine off.
11 E94 error code
displayed.
Temperature
sensor TH1 for
IGBTs is an open
circuit.
The Welding Power
Source's temperature
sensors have
malfunctioned.
Have an Accredited
Cigweld Service Provider
check or replace the
temperature sensors.
Weld current
ceases. Buzzer
sounds constantly.
Switch machine off.
A Main on/off switch on
machine has been
turned off.
A Turn on/off switch on.
B Mains supply (input)
voltage has been turned
off.
B Have an Accredited
Cigweld Service Provider
or a qualified electrician
check the Main voltage
and fuses.
Weld current
ceases. Buzzer
sounds constantly.
Must switch
machine off then
on to reset E99
error.
Possible Cause
Description
Remedy
12 E99 error code
displayed.
Mains supply
(input) voltage
has been turned
off, but control
circuit has power
from the primary
capacitors.
Содержание TRANSTIG 200 AC/DC
Страница 8: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 20: ...TRANSTIG 200 AC DC SERVICE MANUAL 2 6 January 17 2008 NOTES ...
Страница 34: ...5 2 January 17 2008 TRANSTIG 200 AC DC SERVICE MANUAL NOTES ...
Страница 58: ...January 17 2008 11 2 TRANSTIG 200 AC DC SERVICE MANUAL NOTES ...
Страница 74: ...TRANSTIG 200 AC DC SERVICE MANUAL January 17 2008 12 16 THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 111: ...THIS PAGE LEFT INTENTIONALLY BLANK SERVICE MANUAL TRANSTIG 200 AC DC January 17 2008 13 37 ...
Страница 122: ...A 11 January 17 2008 TRANSTIG 200 AC DC SERVICE MANUAL NOTES ...
Страница 126: ......