Message Code
Error
Cause
Possible Remedy
Power Section Fault
Power Section start
up Fault
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Temperature Sensor
Secondary Diode
Defective Thermal
Sensor
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Temperature Sensor
Primary Module
Defective Thermal
Sensor
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Temperature Sensor
Transformer
Defective Thermal
Sensor
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Temperature Sensor
PFC
Defective Thermal
Sensor
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Internal Supply Voltage Internal Supply Voltage
Fault
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Current Detection
Current Detection Fault Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Shutdown due to over
current
Mains Supply Current
is too high
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
HF Ignition Faulty
HF Ignition Faulty
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
Mains Supply Under
Voltage
Mains Supply Voltage
is too low
Check Mains Supply
Voltage
T h e E l e c t r o d e i s
shorted to work piece
when machine is
turned ON
VRD defective, or short
circuit between torch
and work piece
Switch OFF and ON the
power source to clear the
error code
Configuration Error
D e f e c t i v e P C B ,
i n c o r r e c t s y s t e m
software
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source
C o n t r o l P a n e l
identification
C o n t r o l P a n e l
identification error
Have an Accredited
C I G W E L D S e r v i c e
Provider check the power
source