2-5
March 31, 2008
SERVICE MANUAL
TRANSTIG 200 Pi
2.08 Specifications
Parameter
Transtig 200Pi
Power Source Part Number
700720
Cooling
Fan Cooled
Welder Type
Inverter Power Source
Welding Power Source Mass
8kg
Dimensions
H 260mm x W 130mm x L 320mm
Manufactured to Australian Standard
AS 60974.1-2006
Number of Phases
1
Nominal Supply Voltage
240V ±15%
Nominal Supply Frequency
50Hz
Protection Class
IP23S
Standard Specifications (Applicable with factory fitted Supply Plug)
Parameter
Transtig 200Pi
Welding Current Range
5 - 200 Amps
Open Circuit Voltage
65V
Factory Fitted Supply Plug Rating
15 Amps
Effective Input Current (I1eff)
15 Amps
Maximum Input Current (I1 max)
36.7 Amps
Single Phase Generator Requirement
8.8 KVA
Welding Output 40
0
C, 10 min
(Quoted figures refer to MMAW output)
160A @ 15%, 26.4V
80A @ 60%, 23.2V
62A @ 100%, 22.5V
Welding Output 40
0
C, 10 min
(Quoted figures refer to GTAW output)
200A @ 20%, 18.0V
130A @ 60%, 15.2V
100A @ 100%, 14.0V
Upgraded Specifications (Applicable with upgraded Supply Plug)
Parameter
Transtig 200Pi
Welding Current Range
5 - 200 Amps
Open Circuit Voltage
65V
Upgraded Supply Plug Rating Required
25 Amps
Effective Input Current (I1eff)
21.7 Amps
Maximum Input Current (I1 max)
36.7 Amps
Single Phase Generator Requirement
8.8 KVA
Welding Output 40
0
C, 10 min
(Quoted figures refer to MMAW output)
160A @ 35%, 26.4V
130A @ 60%, 25.2V
100A @ 100%, 24.0V
Welding Output 40
0
C, 10 min
(Quoted figures refer to GTAW output)
200A @ 20%, 18.0V
130A @ 60%, 15.2V
100A @ 100%, 14.0V
Table 2-1: Specifications
Cigweld continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of
equipment previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above
specifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured
components, installation location and conditions and local power grid supply conditions.