TRANSTIG 170Pi
TROUBLESHOOTING
6-8 Manual 0-5242
DIODE Testing
Multimeter Lead Placement
Diode Voltage
DIODE V7 & V7-1
Positive meter lead to TP 11
Negative meter lead to TP 12
0.2 – 0.8 VDC
DIODE T14, T15, T18
Positive meter lead to TP 13
Negative meter lead to TP 14
0.2 – 0.8 VDC
DIODE T16, T17, T19
Positive meter lead to TP 15
Negative meter lead to TP 16
0.2 – 0.8 VDC
Table 6-7: Diodes, Multimeter set to measure Diode Voltage
6.09 Check Main Input Rectifier
Art # A-11815
Figure 6-5: Check Main Input Rectifier
Input Rectifier Testing
Multimeter Lead Placement
Diode Voltage
AC1 to DC+
Positive meter lead to 17
Negative meter lead to TP 18
0.2 – 0.8 VDC
AC2 to DC+
Positive meter lead to 19
Negative meter lead to TP 18
0.2 – 0.8 VDC
AC1 to DC-
Positive meter lead to TP 17
Negative meter lead to TP 20
0.2 – 0.8 VDC
AC2 to DC-
Positive meter lead to TP 19
Negative meter lead to TP 20
0.2 – 0.8 VDC
Table 6-8: Input Rectifier, Multimeter set to measure Diode Voltage
Содержание 170Oi
Страница 6: ......
Страница 16: ...TRANSTIG 170Pi GENERAL INFORMATION 1 10 Manual 0 5242 Notes ...
Страница 20: ...TRANSTIG 170Pi INTRODUCTION 2 4 Manual 0 5242 Notes ...
Страница 26: ...TRANSTIG 170Pi INSTALLATION 3 6 Manual 0 5242 Notes ...
Страница 44: ...TRANSTIG 170Pi OPERATION 4 18 Manual 0 5242 Notes ...
Страница 46: ...TRANSTIG 170Pi INTRODUCTION 5 2 Manual 0 5242 Notes ...
Страница 66: ...TRANSTIG 170Pi TROUBLESHOOTING 6 20 Manual 0 5242 Notes ...
Страница 80: ...TRANSTIG 170Pi ASSEMBLY PROCEDURE 8 6 Manual 0 5242 Notes ...