
TRANSTIG 170Pi
Manual 0-5242
6-5
TROUBLESHOOTING
6.05 Test Equipment and Tools for Troubleshooting and Servicing
Art # A-09849
Figure 6-2: Test Equipment and Tools
• Digital Multimeter
• DC clip-on ammeter
• Screwdriver and spanner
• CRO (20 Mhz bandwidth) & isolating transformer
6.06 Visually Inspect
Visually inspect the inside of the Power Source. The levels of current present in these units can cause burning
or arcing of PCB, transformers, switches, or rectifier when a failure occurs. Carefully inspect all components
within these units.
Look in particular for the following:
a) Loose or broken wires or connectors.
b) Burned or scorched parts or wires or evidence of arcing.
c) Any accumulation of metal dust or filings that may have caused shorting or arcing.
If any parts are damaged, they must be replaced. Refer to the Spare Parts section for a complete list of com-
ponents used in the Power Source.
Locate the faulty component(s) then replace where necessary.
Содержание 170Oi
Страница 6: ......
Страница 16: ...TRANSTIG 170Pi GENERAL INFORMATION 1 10 Manual 0 5242 Notes ...
Страница 20: ...TRANSTIG 170Pi INTRODUCTION 2 4 Manual 0 5242 Notes ...
Страница 26: ...TRANSTIG 170Pi INSTALLATION 3 6 Manual 0 5242 Notes ...
Страница 44: ...TRANSTIG 170Pi OPERATION 4 18 Manual 0 5242 Notes ...
Страница 46: ...TRANSTIG 170Pi INTRODUCTION 5 2 Manual 0 5242 Notes ...
Страница 66: ...TRANSTIG 170Pi TROUBLESHOOTING 6 20 Manual 0 5242 Notes ...
Страница 80: ...TRANSTIG 170Pi ASSEMBLY PROCEDURE 8 6 Manual 0 5242 Notes ...
Страница 84: ...TRANSTIG 170Pi KEY SPARE PARTS 9 4 Manual 0 5242 Notes ...