Z22020-01
When the preferred ambient temperature is reached, turn the knob
❺
anti-
clockwise until the red light
❹
goes off.
After a few hours of operation, you can change the temperature setting by
turning the knob clockwise to increase temperature or anti-clockwise to reduce it. This
enables you to set your desired temperature.
4.3 Booster function
This function provides additional heat when you have a bath or shower, while
also drying or warming your towels.
When this function is activated, the radiator operates at maximum output
regardless of the thermostat setting.
Once initiated the booster function runs for 2 hours. It can be stopped at any
time.
There are 2 ways of starting the Booster function:
• Basic, manual booster
• Programmed booster
MANUAL BOOSTER
This function enables the radiator to reach optimum temperature rapidly and
independently of the thermostat setting.
Hold down button
❸
for a few seconds. The red indicator
❹
will flash for
2 hours. The radiator automatically returns to heating mode at the end of the cycle.
You can stop the function by holding down button
❸
; the indicator will stop
flashing.
PROGRAMMED BOOSTER: TIMERPROG
This enables the booster start time to be programmed so that it comes on at the
same time everyday. User-friendly programming: no time to set, no complicated menu!
By pressing button
❸
for 5 seconds, you can record the time the booster was
activated (i.e. when the button was pressed). The indicator
❹
flashes in three series of
three to indicate that the programmed booster is activated. After this series of flashes,
the indicator flashes normally to indicate that the TIMER is on.
The booster will now start every day 30 minutes before the recorded time.
Example:
- Day 1: 7 AM.
Press down for 5 seconds, the indicator flashes (in three series of three), the
time is recorded. The Booster is on.
- Day 2: 6:30 AM, the Booster comes on for a 2-hour period.
The programmed setting can be cancelled by turning the appliance off (button
❶
).
The manual
TIMER
can be activated without affecting the programmed booster.
As with manual operation, the programmed booster can be stopped by pressing
button
❸
without affecting the programmed setting.
4.4 Programming by pilot wire (option)
Your appliance can be regulated by a 6-command programming unit
(
COMFORT
,
COMFORT
-1°C
,
COMFORT
-2°C
,
ECO
,
FREEZE PROTECTION
,
HEATING STOP
).
Commands received
Oscilloscopes
Ref./Neutral
Mode
obtained
Results obtained
No current
Comfort
The temperature obtained is
that of the thermostat setting.
Alternation
* no current: 4’57’’
* phase 230 V: 3’’
Comfort
-1°C
The temperature obtained is
that of the thermostat setting
- 1°C.
Alternation
* no current: 4’53’’
* phase 230 V: 7’’
Comfort
-2°C
The temperature obtained is
that of the thermostat setting
- 2°C.
Complete alternation 230 V
Eco
Economy temperature.
Negative semi-alternance
-115 V
Freeze
protection
Freeze protection
temperature of approx 7°C.
Can be used for load-shedding.
Positive semi-alternation
+115 V
Heating
stop
Immediate stopping of
appliance.