CICLOSPORT HAC 4000 Скачать руководство пользователя страница 8

The following applies for all sub-functions: 
Sub-functions are displayed for 10 seconds, then the main function 
appears again. To premature quit the sub-function, press short the 
UL- or LL-button.

5. 1 Upper display indications

Main functions are chosen with UR-button, sub-functions with UL-
button. To better distinguish 

main functions

 from sub-functions, 

main functions are printed in a bold script and 

sub-functions 

are 

printed in a bold, cursive script.

Speed 

(only in Bike mode and Ski mode)
Indicates the current speed in km/h 
(or mph = miles per hour).
Following applies only in Ski mode: Calculates 
the speed out of  the current decreasing (dis-
played speed can vary up to ±10% ; the more steeply or levelly the 
slope, the more can the value vary).
Range: 0 - 199,9 km/h or 124,2 mph 

Average speed 

 

(only in Bike mode and Ski mode)
Sub-function of function ‚Speed‘.
Indicates the average speed 
(of the bike adjusted).
Range: 0 - 199,9 km/h or 124,2 mph 

Total average speed (bike 1 and bike 2)

(only in Bike mode and Ski mode)
Sub-function of function ‚Speed‘.
Indicates the calculated average speed of bike 
1 and bike 2.
Range: 0 - 199,9 km/h or 124,2 mph 

Maximum speed

(only in Bike mode and Ski mode)
Sub-function of function ‚Speed‘.
Indicates the maximum speed reached with the 
adjusted bike.
Range: 0 - 199,9 km/h or 124,2 mph 

Maximum speed bike 1 or bike 2

(only in Bike mode and Ski mode)
Sub-function of function ‚Speed‘.
Indicates the absolute maximum speed 
reached and also the bike with which it was 
achieved.
Range: 0 - 199,9 km/h or 124,2 mph 

Current heart rate

Setting range: 30 to 240 bpm 
(beats per minute; if value is over 200, the last 
digit is displayed on the comma digit of the 
upper display)
Indicates the current heart rate.

Note:

 Heart rate functions can only be indicated with the 

HAC

, if the accompanying transmitter belt is worn.  

The heart rate functions have an energy-saving mode: if no signal is 
received within a period of approx. 5 minutes, the heart rate receiver 
of the 

HAC

 switches off automatically (symbol ‚heart‘ in the 

display disappears). To reactivate the heart rate receiver , choose 
again the function ‚Current heart rate‘ in the display.

Average heart rate

Sub-function of function ‚Current heart rate‘

Indicates the average heart rate. 

Range: 30 to 240 bpm

Maximum heart rate

Sub-function of function ‚Current heart rate‘
Indicates the maximum heart rate. 
Range: 30 to 240 bpm

Recuperating heart rate

Sub-function of function ‚Current heart rate‘
Indicates the recuperating heart rate (see  
chap. 6.3).  
Recuperating heart rate is the heart rate 
measured 3 minutes after the recuperating 
heart rate function is started (press UL- and 
LL-button short and simultaneous). After 3 minutes a short signal 
tones, when the measuring ends. The display indicates the heart 
rate measured at start of this function and below the recuperating 
heart rate (measured after 3 minutes).
Range: 30 to 240 bpm

Current ascent / descent 

(only in bike mode)
Indicates the current ascent or descent ridden 
at the moment (in %). The arrow on the right 
side of the display indicates if an ascent or a 
descent is measured.
Range: 0% to 99%

Note:

 Technically restricted the correct value is indicated a few 

seconds after the beginning of the ascent/descent.
After stopping (speed = 0) the last value remains in the display.

Average ascent

(only in bike mode)
Sub-function of function ‚Current ascent/des-
cent‘
Indicates the average ascent of the current tour.
Range: 0% to 99%

Average descent 

 

(only in bike mode)
Sub-function of function ‚Current ascent/des-
cent‘
Indicates the average descent of the current 
tour.
Range: 0% to 99%

Maximum ascent

 

(only in bike mode)
Sub-function of function ‚Current ascent/des-
cent‘
Indicates the maximum ascent of the current 
tour.
Range: 0% to 99%

Maximum descent

 

(only in bike mode)
Sub-function of function ‚Current ascent/des-
cent‘
Indicates the maximum descent of the current 
tour.
Range: 0% to 99

Current gain or loss in altitude
(Variometer function)

Indicates the current gain or loss in altitude in 
meters/ft x10 per minute. The arrow on the 
right side of the display shows if it is an ascent 
or a descent. 
Range: 0 to 199 m/min resp. 0 to 65 ft x10/min

Note: 

Technically restricted the correct value is indicated a few 

seconds after choosing this function.

Содержание HAC 4000

Страница 1: ...CicloSport K W Hochschorner GmbH Konrad Zuse Bogen 8 D 82152 Krailling Internet www ciclosport de e mail ciclosport ciclosport de HAC 4000 Instruction manual...

Страница 2: ...1 and bike 2 8 Maximum speed 8 Maximum speed bike 1 or bike 2 8 Current heart rate 8 Average heart rate 8 Maximum heart rate 8 Recuperating heart rate 8 Current ascent descent 8 Average ascent 8 Aver...

Страница 3: ...not slip If the breast belt is not long enough a longer breast belt can be acquired from your local bicycle dealer If your skin is too cold or too dry the electrical contact between the skin and the e...

Страница 4: ...4 seconds In order to quit a setting mode premature press either the UR or LR button again for 4 seconds The following applies to both setting modes Pressing the respective button mode 1 UR mode 2 LR...

Страница 5: ...ith UL or LL button Standard value 70 kg Setting range min 30 kg 66 lbs max 200 kg 441 lbs The body weight is needed for the CICLO Zone calculation AGE age Set with UL or LL button Standard value 30 y...

Страница 6: ...dication is selected automatically also the american date format month day and weight unit lbs is chosen U3 Unit Celsius Fahrenheit Select with UL or LL button The unit of measure for the temperature...

Страница 7: ...all total values and also all daily values To reset press both left buttons short simultaneous Now all settings are done and the HAC is ready for use 5 Functions Important For the HAC to calculate an...

Страница 8: ...the display disappears To reactivate the heart rate receiver choose again the function Current heart rate in the display Average heart rate Sub function of function Current heart rate Indicates the av...

Страница 9: ...Sub function of the function Temperature Indicates the highest temperature measured during the tour Range 20 to 60 C resp 20 to 140 F 5 2 Lower display indications Main functions are chosen with LR bu...

Страница 10: ...tour Range 0 240 rpm Maximum cadence only in bike mode Sub function of function Cadence Indicates the maximum cadence of the current tour Range 0 240 rpm Number of revolutions only in bike mode Sub f...

Страница 11: ...ps of 20 W Note The indicated performance values are approximate They are calculated under the assumption of an average friction wind speed good surface nature of the street and the set total weight T...

Страница 12: ...ours training when memory interval is set to 20 sec For this a recording must be started by pressing UL and LL button simultaneous for 4 sec During this recording all important information such as hea...

Страница 13: ...ifference in time To cancel the comparison premature press again UL and LL button simul taneous for 4 sec coincidentally the recording is stopped In order to compare tours these tour must be previousl...

Страница 14: ...elt clean Do not wash the transmitter belt in a washing machine due to the attached electrodes To clean the transmitter belt wipe it carefully with a detergent for synthetic fabrics Do not dry in dire...

Страница 15: ...evice will be sent back COD 11 Technical data HAC Water resistant 30 m not suitable for swimming do not press any button when wet Operating temperature 20 C to 50 C Battery Lithium CR2032 Average batt...

Отзывы: