Cichewicz Futura Bio 100 Скачать руководство пользователя страница 2

  

 

 

1. Introduction

Thank you for choosing our Company and buying our product. We are convinced that our boiler will operate safely for many 

The boilers of the Futura series are recommended for users seeking modern solutions in combustion of solid fuels.

This instruction manual contains all basic information concerning the design, installation and operation of your boiler. If you 

read this instruction manual thoroughly and follow all instructions and recommendations, long-term and safe operation of the 

boiler will be ensured.

We recommend entrusting the installation of your boiler to authorised installers, who are trained in the area of installation of 

our boilers.

2. The purpose of Futura Bio series boilers

In Poland, biomass as the fuel for boilers becomes more and more popular and commonly used by entrepreneurs and 

farmers. It is utilised for generating thermal energy during the process of combustion in special devices designed for this 

purpose.

One of these devices is the Futura Bio series boiler in the Pellets or Standard version.

 

Purpose and possible use of Futura Bio series boilers

The Futura Bio boilers are designed for burning biomass 

in the form of briquettes, sawdust and chips of proper size 

and, as a substitute, grains or cherry stones.

The Bio Pellets version presented here is designed 

for burning of pellets, i.e. granulated sawdust, with 

diameter of 6 – 10 mm and up to 4 cm. Also, sawdust 

can be burnt as a substitute. For special orders the boiler 

in this version can be adopted for burning of wood chips as large as 30 mm.

The boiler may be installed both in new and revamped boiler rooms with the aim of combustion process automation, 

improving the operating comfort and reducing of harmful emissions to atmosphere. 

 

The Futura Bio boilers with built-in biomass burner can be used for heating of residential buildings, commercial 

buildings, shops, detached houses and so on.

The Futura boilers may be installed only in open-radiant type systems with forced or gravitational circulation, 

complying  with  the  Polish  standard  PN-91/B-02413: ”Heating  and  heat  engineering.  Protection  of  open-type 

water-based heating systems.”

   All works related to boiler room equipment, boiler installation and operation must be performed in compliance 

with valid standards and regulations.

Basic fuel for the Futura Bio Standard boilers:

For the Futura Bio Standard boiler with automatic fuel feeding the following fuels are recommended:

-   Sawdust briquettes with diameter of 50 mm;

-   Wood chips with maximum size of up to 3 cm;

-   Sawdust with maximum content of non-combustible particles of 10%.

should not be less than 16 MJ/kg.

the lifetime of boiler.

Substitute fuel for Futura Bio Standard boilers:

-   Corn straw briquettes with diameter of 50 mm (when not too hard, 80 mm is allowed),

-   Grains: oat,

-   Sweet and sour cherry pits.

Basic fuel for Futura Bio Pellets boiler:

The Futura Pellets series boilers are designed for burning of sawdust biomass in the form of pellets with the diameter of 

6-10 mm and length of up to 50 mm.

Pellets should meet the requirements of the ÖNORM M7 135 standard.

Substitute fuel for Futura Bio Pellets boilers:

-   Wood chips with maximum size of 25 mm.

Fuel recommendations:

Please remember that fuel pieces fed by the feeder should be of a proper size and fuel should not contain pieces greater 

than maximum allowable size recommended. Furthermore, fuel must not contain foreign bodies like stones, plastic or 

metal parts, cords, textiles, fabrics and so on). 

Moisture content higher than recommended will accelerate the corrosion processes and cause premature wear of boiler 

components. Damages caused by above mentioned reasons are not covered by manufacturer’s guarantee. 

Содержание Futura Bio 100

Страница 1: ...g means saving Futura Bio Pellets Congratulations on your purchase of a modern energy saving biomass fired boiler for central heating purposes Basic fuel Futura BIO Standard boilers sawdust briquettes...

Страница 2: ...ere The Futura Bio boilers with built in biomass burner can be used for heating of residential buildings commercial buildings shops detached houses and so on The Futura boilers may be installed only i...

Страница 3: ...combustion tubes On the front side the boiler has a door to the combustion chamber a hand hole for cleaning of convection ducts and in 25 200 kW with ash box doors The doors exposed to high temperatu...

Страница 4: ...ches Fuse box Fuel tank Mixer Feeding screw drive system Feeding screw Mixers drive Protection wax valve Electrical connections Safety coil Stub pipe for connecting of flow out thermal protection Retu...

Страница 5: ...5 Figure Boiler dimensions 50 kW models Figure Boiler dimensions 75 kW and 100 kW models Figure Boiler dimensions 150 kW models Figure Boiler dimensions 200 250 and 300 350 kW models...

Страница 6: ...sions with extended feeding screw Hinges Actuator Plasticized PVC knob Hold down clamp Fuse box Water tank Rubber hose Clean out hole Gear cover Feeder screw Feeder screw Motor Mixer gear Motor Feeder...

Страница 7: ...upon special order All data presented above is for information purposes only and is subject to changes due to continuous product development Dimensions of boiler and tank may differ from given above B...

Страница 8: ...the design of Futura Bio Pellets boiler with fuel tank and feeding system Mounting of fuel tank in the Futura Bio Pellets boiler is made upon individual orders the capacity and dimensions of fuel tan...

Страница 9: ...l feeder drive 8 Charging duct 9 Burner charging feeder 10 Burner charging drive 11 Forced draught fan 12 Fuel igniter 13 Burner with cast iron insert Fuel tank Fuel mixer with cone and blades Mixer d...

Страница 10: ...10 Top Front Back Left side Figure Dimensions of Bio Pellets 100 kW boiler Figure Dimensions of Bio Pellets 200 250 kW boiler...

Страница 11: ...r source otherwise a risk of electric shock may occur 6 Fuel can be charged only when fuel feeder is stopped General requirements The boiler room where the boiler is to be installed must meet the requ...

Страница 12: ...lass C3 this safe distance must be increased to 400 mm If the inflammability of materials is very high the safe distances specified above must be doubled Flammability classes of materials The boiler l...

Страница 13: ...e licences The external equipment and boiler accessories if any should be connected according to the markings to power supply outputs located on the back cover of boiler housing Electric diagram is al...

Страница 14: ...ting devices and expansion vessels No isolating valves are allowed between the boiler and expansion vessel The hydraulic system of boiler room must ensure the minimum return water temperature at the l...

Страница 15: ...Pressure reducer Domestic cold water Pressure gauge Three way mixing valve thermostatic valve Requirements for boiler water Water used for filling the boiler and central heating system should meet th...

Страница 16: ...ting valve opens at temperature of 95 98 C i e type SYR 3065 6 Safety valve 7 Cleaning funnel 8 Thermal outflow protection sensor temperature controlled valve 9 Connector for connecting the thermal ou...

Страница 17: ...n duct should have the cross sectional area equal to one half of chimney cross section area but its dimensions should never be less than 20 x 20 cm The air supply duct should be made of non combustibl...

Страница 18: ...ycle for minimum and maximum boiler output see instruction manual for boiler controller 6 Fuel feeding times should be so programmed that the previous fuel portion burns completely before the fuel doe...

Страница 19: ...ks at least Walls of combustion chamber can be cleaned through charging door Check if there isn t too much waste material in charging hopper and remove if necessary Once a month the boiler should be d...

Страница 20: ...arings do not need maintenance or re lubricating for the period of 20 000 working hours but no longer than three years Upon expiration of above period of time it is recommended to replace motor bearin...