![CIAT PowerCiat LX HE Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/ciat/powerciat-lx-he/powerciat-lx-he_instruction-manual_2606751021.webp)
EN-
21
POWERCIAT LX ST/HE/XE
4.2 - Electrical data
LX XE 0808 to 2158 units
LX XE
0808 0908 1008 1108 1358 1528 1858 2008 2158 2308 2528 2628 3028
Power circuit supply
Nominal voltage
V-ph-Hz
400-3-50
Voltage range
V
360-440
Control circuit supply
24 V via internal transformer
Maximum operating input power
(1)
Standard unit
kW
116 130 144 164 191 209 258 278 313 332 361 385 446
Unit + Xtra / Super Low Noise option
kW
112 126 140 159 186 204 251 271 305 324 352 377 437
Power factor at maximum power
(2)
Displacement Power Factor (Cos Phi)+
0,88 0,88 0,88 0,88 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,90 0,90
Displacement Power Factor (Cos Phi) unit + Xtra / Super Low noise
option
0,88 0,88 0,88 0,88 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,90 0,90
Nominal operating current draw
(3)
Standard unit
A
146 162 178 205 236 257 318 342 393 414 430 486 524
Unit + Xtra / Super Low Noise option
A
140 156 172 197 228 248 307 330 381 402 416 472 510
Maximum operating current draw (Un)
(1)
Standard unit
A
190 212 234 268 309 339 417 450 505 535 581 620 718
Unit + Xtra / Super Low Noise option
A
184 206 228 260 301 330 406 438 493 523 567 606 704
Maximum current (Un-10 %)
(2)
Standard unit
A
190 212 234 268 309 339 417 450 505 535 581 620 718
Unit + Xtra / Super Low Noise option
A
184 206 228 260 301 330 406 438 493 523 567 606 704
Start-up current
(3)+(4)
Standard unit
A
207 218 218 338 434 434 481 480 664 679 679 721 742
Unit + Xtra / Super Low Noise option
A
204 215 215 335 431 431 476 474 659 674 674 715 736
Maximum start-up current (Un)
(2)+(3)
Standard unit
A
207 218 218 338 434 434 481 480 664 679 679 721 742
Unit + Xtra / Super Low Noise option
A
204 215 215 335 431 431 476 474 659 674 674 715 736
(1) Values at the unit's permanent maximum operating condition (as shown on the unit's nameplate).
(2) Values at the unit's maximum operating condition (as shown on the unit's nameplate).
(3) Maximum operating current of the smallest compressor(s) + fan c locked rotor current of the largest compressor.
(4) Standardised EUROVENT conditions, water-cooled heat exchanger water inlet/outlet = 12 °C/7 °C, outdoor air temperature = 35 °C.
4 - PHYSICAL PROPERTIES AND ELECTRICAL DATA FOR LX UNITS