background image

4.4 Settings parameters menu

No.

Description

Unit

Min.

Max.

By default Increment Possible choices

Visibility

Levels

P100 Language

-

0

1

0

1

0 - French

1

1 - English

P101 Time

-

00:00

23:59

00:00

1

-

-

1

P102 Date

-

01/01/2010

31/12/2050

01/01/2014

1

-

-

1

P110 Operating mode

-

0

2

2

1

0 - Cooling

If coil type = mixed

2

1 - Heating
2 - Auto

P111 Operation type

-

0

2

0

1

0 - Comfort 

-

1

1 - Eco
2 - Frost protection

P112 Eco/comfort selection

-

0

2

0

1

0: Time sched. or CMS
1: On/Off input only
2: On/Off input override

P115 Return air/fresh air

-

0

1

0

1

0 - Return air

If damper present

fresh air = YES

2

1 - Fresh air

P117 Air heater fan override

-

0

1

0

1

0 - Auto

-

1

1 - Man.

P118 Fan override speed

%

0

Air heater fan 

max. speed

50

1

-

If fan override = Man.

1

P119 Fan override time delay

min.

0

180

30

1

-

If fan override = Man.

1

P120 Air heater fan min. speed

%

0

Air heater 

max. speed

0

1

-

-

2

P121 Air heater fan max. speed

%

air heater 

min. speed

Calculated 

max. speed

100

1

-

2

P122 TPL min. speed

%

0

TPL max. 

speed

0

1

-

If present TPL = YES

1

P123 TPL maximum speed

%

TPL min. 

speed

100

100

1

-

If present TPL = YES

1

P130 Hot Proportional Band op.

°C

1

10

3

0.5

-

If coil type = heating 

or mixed

2

P131 Hot integration time op.

min.

0

30

Def.

1

If coil type = heating 

or mixed

2

P135 Cold Proportional Band op.

°C

1

10

3

0.5

-

If coil type = cooling or 

mixed

2

P136 Cold integration time op.

min.

0

30

Def.

1

-

If coil type = cooling or 

mixed

2

P140 High temperature fault 

threshold

°C

Stp + Band

75

24

1

-

-

2

P141 High temperature fault time 

delay

s

60

300

120

1

-

-

2

P142 Low temperature fault 

threshold

°C

10

Stp + Band

12

1

-

-

2

P143 Low temperature fault time 

delay

s

60

300

120

1

-

-

2

1-PH HEE BOX 

EN-14  

Содержание 1-PH HEE BOX

Страница 1: ...1 PH HEE BOX 05 2019 EN7515391 02 Control manual...

Страница 2: ...1 PH HEE BOX EN 2...

Страница 3: ...2 Addressing the pLAN 11 4 GENERAL DESCRIPTION OF THE SCREENS 11 4 1 Machine state 11 4 2 Setpoint menu 13 4 3 Machine parameters menu 13 4 4 Settings parameters menu 14 4 5 Read only parameters menu...

Страница 4: ...The password protected configuration and operating parameters Device running times and time delays The connection with the pLAN network allows the program to use a terminal mounted on the front of the...

Страница 5: ...port Modbus BACnet LON KNX On Off inputs 0 10 V analogue outputs 1 4 Description of the air handling units The unit can perform the following functions Ventilation Control monitoring reporting and reg...

Страница 6: ...rox 5 seconds the page shown below will be displayed with the cursor flashing in the top left corner Terminal config Press Enter To continue To change the controller address I O Board address press tw...

Страница 7: ...Switch it back on again and then immediately press and for approx 15 seconds pLan address 1 UP increase DOWN decrease ENTER save exit Change the pLan address to 2 by pressing then press If there are...

Страница 8: ...hange the Display address setting from 00 to 32 by pressing then press Display address Changed Press and again for approx 5 seconds the page below will display Display address Setting 32 I O Board add...

Страница 9: ...nd keys for approx 5 seconds the page shown below will be displayed with the cursor flashing in the top left corner Display address Setting 32 I O Board address Change the I O Board address by pressin...

Страница 10: ...pear the pLAN may be unstable or more likely two components share the same address The number after Term indicates the address of the terminal used The example shows that the network is made up of 3 c...

Страница 11: ...aster controller Address 2 Master controller Address 3 Master controller Address 31 4 GENERAL DESCRIPTION OF THE SCREENS 4 1 Machine state U 01 00 00 00 0 c Marche Puissance Totale U 01 Indicates the...

Страница 12: ...your choice simply press The available menus are as follows 1 Setpoints 2 Machine status 4 Mach parameters 5 Adjust params 6 Reading parameter 8 Test mode 9 Timer programming 11 Communication 13 Alar...

Страница 13: ...ers menu No Description Unit Min Max By default Increment Possible choices Visibility Levels Machine parameters menu P01 Unit size a 0 15 0 1 0 2 1 H4300 2 H4351 3 H4352 4 H4353 5 H4401 6 H4402 7 H440...

Страница 14: ...Man 1 P119 Fan override time delay min 0 180 30 1 If fan override Man 1 P120 Air heater fan min speed 0 Air heater max speed 0 1 2 P121 Air heater fan max speed air heater min speed Calculated max sp...

Страница 15: ...coil type mixed 1 P262 Fan operation feedback state C O Open Closed 1 P263 Antifreeze thermostat state C O Open Closed If frost protection thermostat present YES 1 P264 Remote on off command state C O...

Страница 16: ...th and year of yearly time schedule Start time 00 00 End time in hours and minutes of yearly time schedule State Selection of the state during this period Off Comfort Eco Frost protection Note it is n...

Страница 17: ...the key Confirm by pressing ENTER The unit is now in test mode The overrides are cancelled when the unit is set back to on Output Parameter Setting range Default value Access level Mask Air heater fa...

Страница 18: ...c s ACCES NIVEAU 2 Nouveau mot de passe 0000 Non Re enter the new installer password Niveaux acc s ACCES NIVEAU 2 Retour au niveau 2 Non If access level 2 selected and access level 3 If yes back to ac...

Страница 19: ...comfort setpoints either by Parameter P111 local or CMS or time schedule the last order received time schedule or parameter P111 is taken into account the on off input J4 DI6 only depending on the in...

Страница 20: ...alve is closed COMFORT position the 0 10 V signal will depend on the difference between the regulated temperature value room and the setpoint Regulation will only start after a 30 second time delay on...

Страница 21: ...a 30 second time delay on the fan operation feedback contact An integral action must be entered into the parameters 0 100 P 135 Valve ctrl Cooling operation Cold Proportional Band P150 or P151 Cooling...

Страница 22: ...e All possible options are covered by this table Faults Sources Causes Solutions Fan ID3 fan operation feedback Embedded thermistor faulty Circuit breaker Current too high Switch coil See causes Reset...

Страница 23: ...S RTU Speed bds Set in accordance with the CMS speed Address 001 Different to 0 ModBus TCP insert the pCo Web card CIAT code 7119753 and connect it as described in the manual Validating the protocol o...

Страница 24: ...p with the network cable or the earth braid and to properly separate the various cable families control power earth and communication bus A supervision program installed on a PC not supplied by CIAT A...

Страница 25: ...e Disconnect the power supply to the pCO3 card Press the button on the pCOWeb card Keep pressing and switch the power to the pCO3 card back on The green LED on the left flashes then goes off after app...

Страница 26: ...k Go to Administrator Area User name admin Password fadmin Click Configuration then pCO Com In Protocol Modbus Extended OR BACNET IP Baud rate 19200 Then the button Submit The speed baud rate must be...

Страница 27: ...EN 27 1 PH HEE BOX...

Страница 28: ...ielle d Applications Thermiques Corporation with a capital of 26 728 480 Bourg en Bresse Register of Trade and Companies no B 545 620 114 This document is not legally binding As part of our continuous...

Отзывы: