![CIAS Elettronica S.r.l. MURENA PLUS 12 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/cias-elettronica-s-r-l/murena-plus-12/murena-plus-12_installation-manual_2606615044.webp)
©
CIAS Elettronica S.r.l.
Ed.
2.0
Installation Manual
Pag. 43 of 46
Murena Plus 12, 24, Curtain
k) Rotate function switch
SW1 to Position B
and it is possible to read and/or modify
type of ground to adapt the sensor to the characteristics of the ground.
To Read type of ground:
•
Rotate function switch SW2 (units) until the red led (DL9) comes on.
•
Rotate function switch SW3 (tens) until red led (DL8) come on.
The values read on these switches vary between 10 and 11.
Default 10
.
For Murena Plus
Curtain
the values vary between 00 and 01.
Default 00
To Modify type of ground:
•
Rotate function switch SW2 to the values required and SW3 to 1 (10= asphalt,
11= grass). For Murena Plus Curtain rotate function switch SW2 to the values
required and SW3 to 0 (00= asphalt, 01= grass)
•
Press S1 to confirm the setting and to acquire new type of ground.
l) Rotate function switch
SW1 to Position 0 and press button S1
. This concludes the
installation phase.
Leave the switch in this position for normal operation.
5.2 Calibration using Software
For display and extremely accurate management of all the parameters of the detector,
complete with analogue threshold levels and received signals, use the
Wave-Test 2
software running on a PC. Refer to the software manual for connection details and detailed
procedures for the management of the detector.
Analogue Values screenshot for Murena Plus and Murena Plus Curtain