ZRMV
高压固态软起动装置说明书
User’s Manual for ZRMV High Voltage Solid Soft Starter
34
应的输出,另有一个继电器的输出用来控制旁路接触器。
There are three relays on the main board of High Voltage Solid Soft Starter and two of them are programmable.
Customer may set them according to requirement and the rest is designed to control the bypass contactor.
参数
P10
、
P11
、
P12
、
P13
、
P14
:用于设置继电器的输出方式及输出延时。
Parameter P10
、
P11
、
P12
、
P13
、
P14
:
to set function of output and output delay.
全压输出:软起动装置输出电压达到额定电压时输出闭合(所设置的延时时间到)
。
Full voltage: contacts when output voltage reaches rate voltage (and time delay is up).
起动过程输出:软起动装置处于起动过程输出闭合(所设置的延时时间到)
。如果延时时间未到就已经
全压,则不进行输出。
Starting: soft starter is starting motor (and time delay is up). The signal will not put out if voltage increases to
full before the time delay is up.
软停过程输出:软起动装置处于软停车时输出
(
所设置的延时时间到,且其值必须小于参数
F08
所设置
的软停时间
)
。
Soft stopping: the signal put out when soft starter is ramping down (and time delay is up and it is less than the
soft stopping time set by parameter item F08).
故障时输出:软起动装置检测到故障时输出闭合
(
所设置的延时时间到
)
。
Fault: put out the signal when a fault is detected by soft starter (and time delay is up).
刹车时输出:软起动装置处于刹车时输出
(
所设置的延时时间到,且其值必须小于参数
F10
所设置的刹
车时间
)
。
Braking: put out the signal when soft starter is braking (and time delay is up and it is less than the braking time
set by parameter item F10).
运行过程输出:在起动和运行的的整个过程输出(所设置的延时时间到)。
Running: put out the signal during motor starting and running (and time delay is up).
可编程延时输出:参数
P02
必须设置为延时继电器控制输入,相当于是一个内置延时继电器。
Programmable time delay: parameter P02 must set time delay relay input which is regarded as a time delay
relay.
欠载保护输出
(
不做为故障
)
:检测到欠载时输出闭合
(
所设置的延时时间到
)
但不将其作为故障。
Under load protection (does not trip as a fault
):
):
):
):
the signal is put out when under load is detected (and preset
time delay is up) but is not treated as a fault.
定时停车参数
定时停车参数
定时停车参数
定时停车参数(
(
(
(
Parameter for operation timing
)
)
)
)P15
P15
P15
P15
需要设定该参数时,最小设定量为
0.1h
,指当软起动装置运行后,在指定时间到后按照设定的停车方式
进行停车(采用双接点接线控制方式时有效)
。
Minimum set value of this parameter is 0.1h if it is needed. The parameter means High Voltage Solid Soft
Starter will stop motor within the time in preset mode after motor starts up.
(
valid when dual-node control mode is
applied
)
通信及密码保护参数
通信及密码保护参数
通信及密码保护参数
通信及密码保护参数(
(
(
(
Parameters for communication and password lockout
)
)
)
)P16
P16
P16
P16—
—
—
—P17
P17
P17
P17、
、
、
、
P19
P19
P19
P19
在进行网络通讯时,可连接
32
台设备,并可通过
LCD
显示屏查看当前的通讯地址。参数
P19
进行功能
项的密码设置,实现设置参数的密码保护。