04

1. Unit features 

Water Level Detection Sensor

Differed from ordinary float level sensor, the capacitive sensor is used for improving water level
detection accuracy without a float. Capacitive sensor stably detects water level in more reliable
and safer way. The signal from the sensor is sent to a controller in order to automatically adjust
purified water level.

Constant Water Dispensing Function

It enables users to take ambient or cold water constantly by setting constant water function and press-
ing water dispensing button up to 0.5L.

Operation by sensor and Micom

Hot water temp. sensor/room temp. sensor / ice making sensor/ ice full sensor are built in the
machine. Ice making, deicing, and cold water making are operated automatically by Micom and
maintain it at an optimized operation environment. 

Enhanced water leak prevention 

Water leakage stop valve installed on the base panel stops source water inlet immediately to prevent
any damage from water leak.  

Noise Prevention

This reduces system operating noise by applying a dual noise prevention material, utilizing a shock
mitigation structure found at ice storage house.

Display of abnormal occurrence and reinforced safety function

The safety features of the unit have been enhanced in order to prevent various problems from occurring.
The system will inform the user(s) of abnormal occurrences through a flashing display LED and by
automatically stopping the ice making function, water purification function when an abnormality in the
system is detected.

Automatic Water Dispensing

This system function is convenient to the user as it enables ambient water, cold water and hot
water to serve by pressing a button slightly.

Operation Beep Sound

This provides users with sound effects (Ding, Dingdong~ etc) which indicate operation setting upon
pressing button by changing its sound.

Default function

Water selection is programmed to return to cold water selection which is most frequented water
temperature even after ambient water is selected. (Ambient water: 10 seconds later)

11

12

13

14

15

16

17

18

19

Содержание CHP-5321D

Страница 1: ...Rev No 00 2F KOMOS B D 10 DODANG DONG WONMI GU BUCHEON SI GYEONGGI DO KOREA P O BOX 420 800 TEL 82 32 672 7431 FAX 82 32 671 6531 E MAIL goodeal chungho co kr http eng chungho co kr...

Страница 2: ...iffer from the picture Unit appearance specification etc are subject to change without prior notice if necessary for improving unit performance The rated voltage of this unit is AC 230V 50Hz only http...

Страница 3: ...ughly and keep it for your future reference Greetings Table of Contents 1 Unit features 3 4 2 Safety precautions 5 7 3 Installation cautions 8 4 Installation method 9 5 Usage 10 16 5 1 Display and fun...

Страница 4: ...duces only pure ice by freezing point depression method which supplies purified water to ice making unit This method allows the pure water to freeze at 32 F 0 C while non pure water freeze at below th...

Страница 5: ...prevent any damage from water leak Noise Prevention This reduces system operating noise by applying a dual noise prevention material utilizing a shock mitigation structure found at ice storage house...

Страница 6: ...or a place exposed to rain or snow An electric shock or fire may occur Do not put candles lit cigarettes etc on the unit and do not install the unit near a heating appliance There is a danger of a fir...

Страница 7: ...ith the possibility for serious injury or death Danger Symptoms under normal operations 1 During use of the unit a murmuring water flow sound a clattering ice dropping sound etc may occur during cold...

Страница 8: ...tion After transporting the unit do not supply the power for at least 30 minutes to stabilize the unit Do not operate the unit on sloping surface This can cause a malfunction and trouble Do not tilt t...

Страница 9: ...that brine water may not splash around area Brine water can easily be used for other purposes such as bathroom cleaning house cleaning laundering washing etc Never use the drainage water for drinking...

Страница 10: ...0 minutes in order to stabilize the cooling system and safe use of unit Check if water is supplied into the unit properly and there are any leakages on every connection Check every connection part for...

Страница 11: ...cup after selecting the desired water selection among ambient cold or hot HOT TANK HEATING OFF INSTANT HEATING SELECTION SWITCH ON OFF ICE MAKING SWITCH ON OFF Press the switch up and middle and down...

Страница 12: ...5 2 Function setting and releasing Constant water function setting Pressing COLD AMBI HOT SELECTION BUTTON for 2 seconds to take ambient or cold water constantly Setting sound Dingdong Constant ambi e...

Страница 13: ...Press COLD AMBI HOT SELECTION BUTTON for 10 seconds to release beep function WATER FULL ICE FULL HOT ICE LED blinks 5 times Releasing sound Ding Ding 10 seconds 10 seconds Constant water function rel...

Страница 14: ...is served If ambient water is selected and it is not used for 10 seconds the system will automatically switch into cold water dispensing mode which is most frequented Default function There is no sep...

Страница 15: ...releasing Press heating selection switch attached on the rear COLD AMBI HOT LED is changed in accordance with instant heating process as below Yellow Orange Red When instant heaing function is comple...

Страница 16: ...very 4 days when frequency of use is low ACS cleaning function which has UV sterilizer as option provides users with always clean and safe water as any chemical and electrolysis equipment is not used...

Страница 17: ...Ice forming and Ice harvesting action Ice forming action Spray cold water to the evaporator for given time Ice harvesting action Supply heat to the evaporator to remove ice from the evaporator When t...

Страница 18: ...And coffee and beverage etc can make dispensing hole contaminated When ice dispensing hole is splashed with foreign substance such as coffee beverage etc clean up immediately Cleaning is recommended...

Страница 19: ...d pull it out to the bottom Water dispensing spout Turn faucet deco to the left to disconnect it from the body Separate cap from ice dispensing deco and clean them Put the cap back into ice dispensing...

Страница 20: ...by pressing ICE DISPENSING BUTTON Turn the drain switch ON after lifting the filter Cold water and ambient water are automatically drained for 11 minutes Detach the ambient water tank cover after loos...

Страница 21: ...water completely and use it Wash your hands first and put on sanitary gloves Clean up the tank with soft cloth or dry cleaner Do not use chemicals or detergent Discard used cleaner sanitary gloves et...

Страница 22: ...nstall the unit in places below A place exposed to direct sunlight Nearby toilet In front of cooling heating device Self maintenance Checkup Maintenance Clean up water dispensing spout ice dispensing...

Страница 23: ...ough brine tube T Post carbon filter It removes dissolved gases and odors to improve water taste UV sterilizer It sterilizes the bacteria which may exist in source water by UV 9 1 Filter functions 9 2...

Страница 24: ...water Check for water leakage If it is found turn off the unit and shut down source water valve 5 minutes of flushing is necessary before filter replacement Lift the filter and turn to the left and p...

Страница 25: ...r Ambient water Hot water Ice Room temperature Ice making cycle Dailyicemakingcapacity Daily maximum ice making quantity Ice weight IGUASSU TINY 900 Refer to the front page 0 36 Gal 1 4 0 63 Gal 2 4 0...

Страница 26: ...valve 4 5 6 Fitting Booster pump 5 years 3 years 5 years OLC Replacement cycle 3 years 3 years 5 years 3 years This is not warranty period This ideal replacement cycle is to make sure that product wor...

Страница 27: ...n you still have problem as the power plug is inserted properly Is ice making switch is ON Ice is not served Put ice making switch ON Is tap water being supplied Wait until the tap water works Unplug...

Страница 28: ...27 15 MEMO...